Custom caution and safety signs, laser engraved
1,583 laser-engraved lamacoid signs across 40 categories. Add any stock sign below, customize wording in the sign maker, or send a list for a to-scale proof before cutting.
All signs and labels
Danger signs
For hazards that will kill or seriously injure if not avoided. Red plate, white letters, with the word engraved as a reversed band.
Buried cable
Pedestals and above-ground markers.
Keep clear, high voltage
Long, low spots above equipment rows.
High voltage, small
Covers and small doors, adhesive back.
Arc flash hazard, keep out
Switchgear and MCC room doors where energized equipment can be opened.
High voltage, English and French
Bilingual high voltage sign for federal sites and work in Quebec.
4160 volts
Medium-voltage switchgear, starters and transformer doors; change the voltage to suit.
Asbestos dust hazard
Mechanical rooms, ceilings and pipe chases with asbestos-containing material.
Overhead power lines
Yards, laydown areas and loading zones under overhead conductors.
Explosive atmosphere
Entrances to classified hazardous locations: paint booths, fuel handling and solvent rooms.
Substation gate, 27.6 kV
Gates and fences around customer-owned substations and transformer yards; change the voltage to suit, or add your control room number.
13.8 kV cables, strip
Medium-voltage cable trays, pull boxes and cable vault entrances; change the voltage to suit.
Energized work in progress
Hang on the barricade around live electrical work so unqualified people stay outside the approach boundary.
Bare conductors, crane runway
Along crane runways and trolley bus where open conductor bars can be reached from a ladder, lift or walkway.
Oxygen-deficient atmosphere
Rooms, pits and enclosures where nitrogen, argon or carbon dioxide can push out the air.
Hydrogen sulphide (H2S)
Sewage lift stations, wet wells, digesters and any pit or vault where H2S can collect.
Open excavation
Hoarding and fencing around trenches, pits and excavations on construction and utility sites.
347 V lighting, switch tag
Switch plates, fixtures and junction boxes on 347 V lighting circuits, so nobody takes them for 120 V.
Keep out, authorized personnel only
Gates, fences and doors to hazardous areas that only authorized people may enter.
Hazardous area, do not enter
Process areas, tank farms and rooms where a hazard is present beyond the door.
Moving machinery, keep clear
Production lines, packaging cells and mill floors with exposed moving equipment.
Keep hands clear
Machine guards, rollers, feed points and closing parts that can trap a hand.
Amputation hazard
Presses, shears, saws and conveyors with points that can sever fingers or hands.
Workers overhead
Below mezzanines, catwalks, scaffolds and roof work where tools can drop.
Electric fence, do not touch
Along energized security and livestock fences, at gates and corners.
Buried gas line
Markers over underground gas services and private gas lines on site.
Fumigation in progress
Every entrance to a building, silo, container or room being fumigated.
Rotating auger
Auger conveyors, screw feeders, hoppers and bins in farm, food and bulk plants.
Automated storage, keep out
Fences and access doors of automated storage and retrieval systems and shuttle racking.
Fragile roof, do not walk on
Roof hatches and ladders to fibreglass, greenhouse and corroded metal roofs.
Do not cross conveyor
Along conveyor lines next to the nearest crossover bridge.
Warning signs
For hazards that could kill or seriously injure: stored energy, automatic starts, more than one source. Orange plate, black letters.
Fed from more than one source
Panels fed by utility plus generator, PV or a second feeder.
Backfeed possible
Equipment that can be energized from the load side.
Ground fault indicated
Ungrounded and high-resistance grounded systems.
High pressure
Air receivers, hydraulic units, steam.
Hearing protection required
Generator rooms, compressor rooms and plant areas over the noise limit.
Carbon monoxide hazard
Parking garages, generator rooms and shops where engines or heaters run indoors.
Chemical storage area
Chemical rooms, cabinets and storage cages.
Fed from UPS
Panels and receptacles downstream of a UPS that stay live when the utility is off.
External control voltage
Control panels and starters with interlock or control circuits fed from elsewhere.
High leakage current
UPS units, VFDs and filtered equipment that needs a solid ground connection.
Radio frequency energy, antennas
Roof hatches, roof doors and ladders leading to cellular and radio antennas.
Double hearing protection, over 100 dBA
Areas too loud for earplugs or earmuffs alone: chippers, test cells, blowdown and compressor bays.
Combustible dust
Dust collectors, woodshops and grain, flour, sugar or plastics handling, where settled dust can flash or explode.
Welding area, arc rays
Welding bays and fab shops; mount over the bay or on the welding screens.
Compressed air, never on people
Beside air drops, hose reels and blow-gun stations, where workers are tempted to dust themselves off.
UV lamps inside
Air handler and duct access doors with germicidal UV-C lamps, which burn eyes and skin.
Remote start
Pumps, fans and conveyors started from a control room or building automation system.
Never lift loads over people
Hoist and crane control stations and pendant hangers, where the operator sees it before every lift.
Vehicle exhaust, connect hose
Service bays, fire halls and fleet garages with tailpipe exhaust extraction.
Magnetic field
Lifting magnets, magnetic separators, induction heaters and magnetizing equipment.
Hazardous location
Doors to rooms and zones classified for flammable gas, vapour or dust.
Spring under tension
Overhead door torsion springs, dock levellers and spring-loaded equipment, two-hole tag.
Vehicle lift
Beside two-post, four-post and in-ground hoists in garages and fleet shops.
Pool chemicals
Pool chemical storage rooms and pump rooms at condos, hotels, clubs and recreation centres.
Heat stress area
Foundries, bakeries, boiler rooms, laundries and hot plant areas in summer.
Rodent bait station
On or above bait stations in plants, warehouses and kitchens, two-hole tag.
Hydraulic system
Hydraulic power units, presses, lifts and mobile equipment.
Abrasive blasting
Blast rooms, booths and areas where sandblasting or media blasting is done.
Explosion vent, keep clear
Below and beside explosion vents on dust collectors, silos and process buildings.
Lithium-ion charging area
Rooms and cages where tool, e-bike, scooter and equipment batteries are charged.
Wood dust
Woodshops, cabinet and millwork plants, at sanders, saws and dust collectors.
Welding fumes
Welding bays, booths and fabrication shops.
Ozone
Rooms with ozone generators for water treatment, pools, laundries and odour control.
Air compressor starts automatically
On or beside air compressors in shops, plants and garages.
Caution signs
For hazards that could cause minor or moderate injury: hot surfaces, pinch points, noise, traffic. Yellow plate, black letters.
Overhead hazard
Low beams, cable trays and ductwork.
Two sources of supply
Double-ended equipment and tie breakers.
Hot surface, small
Motor housings and covers, adhesive back.
Wet floor, English and French
Washrooms, wash bays and entrances where floors are often wet.
Watch your step, strip
Long, low sign over thresholds, single steps and raised floor edges.
Low clearance
Doorways, ducts and beams over drive aisles; change the height to suit.
Falling ice and snow
Entrances, walkways and parking along eaves and roof edges in winter.
Steep stairs, use handrail
Mezzanine stairs, ship ladders and service stairs to platforms.
Automatic door
Power-operated sliding and swing doors at entrances and between areas.
Step down
Doors and landings with a step down on the far side that people do not expect.
Ramp, sloped floor
Top and bottom of interior ramps and sloped walkways, where the floor changes pitch.
Sharp edges, wear gloves
Sheet metal and glass racks, shears, duct shops and cutting tables.
Heavy cover, two-person lift
Switchboard and transformer covers, deadfronts and floor hatches too heavy for one person to handle.
Door swings out
Corridor side of doors that open into a hallway, stairwell or aisle.
Slow down, yard sign
Yard roads, parking lots and plant driveways where people walk among trucks and cars.
Do not stack above this line
Walls, cages and bins; mount with the bottom edge at the highest safe stacking height.
Do not step, use a ladder
Piping, conduit, cable tray, rooftop units and equipment covers that people treat as a step.
Non-potable water, do not drink
Hose bibbs, wash-up sinks, process water taps and tanks that are not safe to drink from.
Motorized damper, keep hands clear
Duct access doors at motorized and smoke dampers, whose blades can snap shut on fingers.
Store heavy items low
Shelving and cabinets in stockrooms and shops, so heavy stock stays below shoulder height.
Sharp objects
Shipping benches, scrap bins, sheet metal racks and anywhere blades or broken material are handled.
Falling objects, hard hats required
Below racking, mezzanines, conveyors and overhead storage.
Maintenance in progress
Hung at rooms, corridors and equipment while maintenance crews are working.
Wet paint
Reusable plate for doors, railings, walls and floors that were just painted.
Team lift required
Shelving, stock and parts too heavy for one person to lift safely.
Open door slowly
Doors that open onto corridors, stairs or traffic aisles.
Electrical work in progress
Panels, rooms and corridors while electricians are working on circuits.
Do not adjust
Thermostats, valves, set screws and controls that are set and must be left alone, two-hole tag.
Do not lean on railing
Mezzanine, balcony and atrium railings and glass guards.
Pressure test in progress
Piping, tanks and vessels under hydrostatic or pneumatic test.
Damaged rack, do not load
Hung on damaged racking bays until they are repaired or replaced, two-hole tag.
Impalement hazard
Construction and renovation areas with exposed rebar, dowels or stakes.
Fire shutter, keep clear
Above and beside rolling fire shutters at counters, openings and conveyors.
Cable tray, do not step or stand
Strapped to cable trays and wireways where trades use them as a step.
Stretch wrapper
Pallet stretch wrappers with a rotating turntable or arm.
Dock leveller, stand clear
Beside dock leveller controls at each loading door.
Grinding sparks
Grinding stations and fab bays near combustible material or walkways.
Revolving door
Both sides of revolving doors in lobbies and entrances.
Escalator, hold the handrail
Top and bottom landings of escalators and moving walks.
Intense light
UV curing lines, IPL equipment, inspection lamps and high-output lighting.
Aerial lift in use
Set out below scissor lifts and boom lifts while work is overhead.
Notice signs
Information and rules with no hazard to people: access, clearances, housekeeping. Blue plate, white letters.
Electrical room
Electrical room doors.
No storage
Electrical and mechanical rooms.
Keep door closed
Fire separations and controlled rooms.
Employees only
Back-of-house doors.
Out of service
Equipment awaiting repair.
No admittance, English and French
Bilingual door sign for restricted rooms, federal sites and Quebec work.
Escort required
Data halls, control rooms and plant areas where visitors stay with staff.
Video surveillance
Entrances, yards, parking and loading docks with cameras.
Visitors report to office
Site entrances, shipping doors and plant gates.
Hot work permit required
Plants and buildings where welding and cutting need a hot work permit.
Not an exit
Doors to storage, service rooms and dead ends that people could take for a way out.
Authorized vehicles only
Yard gates, service roads and lanes behind plants, substations and loading areas.
No cell phones beyond this point
Production floors, control rooms and secure or clean areas with a no-phone rule.
Deliveries, rear door
Front entrances and offices, sending couriers and freight round to receiving; pick the arrow to suit.
Clean room, gowning required
Gowning room doors for electronics, pharmaceutical and food clean rooms.
Remotely monitored equipment
Generators, pump stations, refrigeration and fire pump rooms watched by a control room or monitoring company.
Keep this area clean
Lunchrooms, kitchenettes, washrooms and shared benches.
Maximum occupancy plate
Meeting rooms, lunchrooms, training rooms and halls; change the number to the room's approved occupant load.
No idling
Loading docks, pick-up zones and parking near building air intakes and doors.
No customers beyond this point
Shop, service bay and warehouse doors in stores, garages and counters open to the public.
All contractors must sign in
Main entrances, shipping doors and maintenance offices at plants and buildings.
No public washrooms
Store and office entrances and counters.
After-hours emergency contact
Building entrances, mechanical rooms and service doors, with your own number engraved.
Scent-free workplace
Entrances, reception desks, clinics and offices with a scent-free policy.
No one under 18 in this area
Shop floors, warehouses and machine areas restricted to adult workers.
Keep gate closed
Yard, fence, pool and compound gates that must not be left open.
Last person out
Beside exit doors and light switches in offices, shops and trailers.
Receiving hours
Shipping and receiving doors, with your own hours engraved.
Designated smoking area
Outdoor smoking shelters and areas set back from entrances, air intakes and fuel.
This door locks automatically
Self-locking doors to rooms, stairwells and yards.
Accessible entrance
At the barrier-free entrance and on the route that leads to it.
Please knock before entering
Office, exam, change room and quiet room doors, two-hole tag.
Quiet zone
Study areas, clinics, control rooms and offices.
Please keep off the grass
Lawns, seeded areas and landscaping at offices, condos and plants.
Please wait here
Reception desks, shipping counters and service windows.
Nut-free zone
Daycares, schools, lunchrooms and offices with a nut-free policy.
Please pick up after your dog
Lawns, walkways and pet areas around condos, apartments and offices.
Area temporarily closed
Reusable plate for rooms, aisles and corridors closed for work or cleaning.
Meeting in progress
Boardroom, training room and office doors.
Safety first & instructions
Green SAFETY FIRST signs for the everyday rules of a safe shop: report injuries and hazards, lift with your legs, hold the handrail, clean up as you go. Plus green plates that mark naloxone kits, stretchers, safety showers and emergency phones.
Report all injuries and near misses
First aid stations, time clocks, lunchrooms and health and safety boards.
See a hazard, report it
Shop floors, warehouses and site trailers, so unsafe conditions get reported and fixed.
Stop and think before you act
Plant entrances, shop floors and site trailers.
Wash hands before eating
Lunchroom doors and wash-up sinks in shops that handle lead, chemicals, oils or soil.
Clean up as you go
Production lines, benches and shop floors where good housekeeping prevents falls and fires.
Hold the handrail
Stairwells, mezzanine stairs and loading dock steps; mount at the top of the flight.
Lift with your legs
Shipping and receiving, stockrooms and anywhere people lift by hand.
Health and safety board header
Over the board where the act, your policy, committee members and inspection reports are posted.
Naloxone kit
Where the kit is kept; Ontario requires one in workplaces where a worker opioid overdose is a risk.
Eye protection available here
Over safety glasses dispensers at shop doors and visitor entrances.
Visitor and contractor orientation
Site gates, reception and plant entrances where everyone signs in and gets an orientation first.
Emergency phone, dial 911
Over phones in plants, parking garages, rooftops and remote work areas.
Stretcher location
Wall brackets and cabinets that hold a stretcher, near the first aid station.
Safety shower
Drench showers in chemical, battery and process areas; mount high so it shows over equipment.
First aid kit inside
Cabinet doors, cupboards, toolboxes and vehicles that hold a first aid kit.
Right to refuse unsafe work
Health and safety boards, lunchrooms and site trailers.
Think safety, work safely
Shop entrances, lunchrooms and time clocks.
Safety is everyone's responsibility
Lobbies, plant entrances, meeting rooms and safety boards.
Good housekeeping prevents accidents
Shops, warehouses and plant floors, near tool cribs and waste bins.
Don't take shortcuts
Machines, maintenance shops and job-site trailers.
When in doubt, ask
New-worker areas, machine stations and shop entrances.
Use the right tool for the job
Tool cribs, benches and maintenance shops.
Work safe, someone is counting on you
Exits, time clocks and parking lot doors.
Look out for each other
Plant floors, job sites and warehouses.
Stretch before you start
Muster areas, shop entrances and warehouse start-of-shift meeting spots.
First aid certified staff
Beside the first aid kit or safety board, with the names of trained staff posted below.
No smoking & prohibition signs
No smoking, no entry, no cell phones, no food or drink, do not touch: the red ring-and-bar signs, engraved red on white or white on red.
No smoking
Entrances, offices, plants and any indoor workplace, with the red no-smoking symbol.
No smoking or vaping within 9 m
Beside entrances, exits and air intakes where smoking and vaping are banned within 9 m.
No smoking, matches or open flames
Fuel, solvent, paint and gas storage areas where any ignition source is banned.
No vaping
Offices, washrooms and common areas where e-cigarettes are not allowed.
No smoking or vaping of tobacco or cannabis
Workplaces, lobbies and common areas that ban tobacco, cannabis and vaping together.
Smoke-free building
Main entrances and lobbies of buildings where smoking and vaping are banned inside.
Smoke-free property
Gates, parking lots and walkways of campuses and sites where smoking is banned everywhere outdoors too.
No smoking in this vehicle
Dashboards and doors of company trucks, vans and forklifts, adhesive back.
No smoking beyond this point
Gates and doorways leading to fuel, chemical, grain or warehouse areas.
No open flames
Rooms with flammable vapours, gases or dust where no flame, spark or torch is allowed.
No hot work
Areas where welding, cutting and grinding are banned outright because of fire or explosion risk.
No unauthorized access
Plant rooms, roofs, server rooms and work areas open only to authorized people.
No riding on conveyors
Along conveyor lines and transfer points where workers might ride or sit on the belt.
No cell phone use while operating
Forklift, crane and machine operator stations and plant traffic routes.
No eating, drinking or smoking
Chemical, lead, battery and lab work areas where hand-to-mouth contact is a hazard.
No climbing
Fences, tanks, towers, stacked material and equipment people are tempted to climb.
No pets, service animals welcome
Entrances to stores, offices, kitchens and plants where pets are not allowed.
No gloves at this machine
Drill presses, lathes, mills and other rotating machines where a glove can be caught.
Do not walk or stand here
Fragile covers, pipe racks, machine tops and surfaces not built to be walked on.
No skateboarding or bicycles
Plazas, ramps, loading docks and walkways on private property.
No headphones or earbuds
Plant floors, warehouses and yards where workers must hear alarms, horns and traffic.
No glass beyond this point
Food processing, packaging and pool areas where broken glass would contaminate product or cut bare feet.
No drones
Fences and gates of plants, substations, construction sites and private property.
No alcohol or cannabis
Entrances, gates and lunchrooms of workplaces with a fit-for-duty policy.
No horseplay
Shops, plant floors, warehouses and lunchrooms.
No e-bikes or e-scooters inside
Condo, apartment and office entrances, elevators and corridors.
No propane cylinders inside
Condo and apartment lobbies, elevators and balconies, and inside commercial buildings.
No barbecues
Balconies, patios and courtyards of condos, apartments and offices.
No space heaters
Offices, server rooms and storage areas where portable heaters are banned.
No daisy-chained power bars
Beside outlets and power bars in offices, labs and workshops, two-hole tag.
No candles or incense
Offices, condos, dorms and care homes that ban open flames indoors.
No contact lenses
Chemical labs and process areas where splashes or vapours can get trapped behind a lens.
Do not flush paper towels or wipes
Inside washroom stalls, above the toilet.
Do not stand on chairs
Offices, classrooms and storerooms where people reach for high shelves.
No littering
Parking lots, loading docks, smoking areas and grounds.
No smoking on balconies
Condo and apartment balconies, patios and courtyards covered by a smoke-free building policy.
No fireworks
Parking lots, rooftops, courtyards and grounds of plants, condos and offices.
Chemical & gas
Storage room, cabinet and cylinder signs for flammables, oxidizers, corrosives, compressed and toxic gases, fuel and used-oil tank tags, plus SDS and spill stations. Engraved plates stand up to splashes and wipe-downs that peel printed stickers.
Flammable cabinet
On flammable storage cabinets, adhesive back.
Natural gas, smell gas
Gas meter, boiler and mechanical rooms.
Carbon dioxide
Bulk CO2 tanks and cylinder rooms in restaurants, breweries and labs.
Ammonia refrigerant
Refrigeration machinery rooms in cold storage, arenas and food plants.
No smoking, bilingual
Fuel, gas and chemical areas in buildings that post in English and French.
SDS station
Where the safety data sheet binder or terminal is kept.
Spill kit
Above spill kits in chemical, fuel and battery areas.
Empty cylinders
Cage sections and racks for empties, kept apart from full cylinders.
Toxic gas storage
Gas cabinets and cylinder rooms for hydrogen sulphide, carbon monoxide, chlorine and other toxic gases.
Water-reactive, keep dry
Storage for sodium, potassium, lithium, metal powders and other materials that react with water.
Oxidizer storage area
Rooms and bays where peroxides, nitrates, chlorates and pool oxidizers are kept.
Oxygen and fuel gas stored apart
Welding shops and cylinder cages where oxygen and acetylene or propane cylinders are stored.
Flammable gas cylinders
Long strip for cylinder cages holding acetylene, propane, hydrogen and other fuel gases.
Forklift propane cylinder storage
Forklift cylinder racks and exchange cages, so cylinders go back the right way up.
Gasoline tank tag
Gasoline tanks, cans and dispensers in fleet yards, farms and shops.
Diesel fuel tank tag
Diesel tanks, generator day tanks and dispensers, in the combustible brown.
Used oil
Used oil tanks and drums in garages and shops, to keep them clean for recycling.
Paint and aerosol storage
Maintenance shop and retail back-room storage for paint, solvents and spray cans.
Battery acid
Battery watering stations and electrolyte storage in forklift charging areas.
Chemical spill response
Beside spill kits and in chemical rooms, so people know the first two moves.
WHMIS-trained personnel only
Chemical rooms, dispensing areas and storage cages that only trained staff should enter.
Bond and ground containers
Drum racks and dispensing stations where flammable liquids are poured or pumped.
Toxic chemicals storage area
Doors of rooms and cages that hold toxic chemicals and poisons.
Pesticide storage
Doors of sheds, rooms and cabinets where pesticides and herbicides are kept.
Sulphuric acid tank tag
Tanks, totes and dosing pumps holding sulphuric acid.
Sodium hydroxide tank tag
Tanks, totes and dosing pumps holding caustic soda.
Sodium hypochlorite tank tag
Bleach and hypochlorite tanks in pool, water and wastewater plants.
Cyanide, keep acids away
Rooms and cabinets where cyanide salts are used or stored, such as plating and mining labs.
Hazardous materials
Door strip for hazmat storage rooms and receiving areas.
Keep away from heat, sparks and flames
Flammable storage, tanks and dispensing points near heaters or hot work.
Stop engine, no smoking while refuelling
Fuel dispensers at yards, marinas, farms and fleet garages.
Full cylinders
Rack or cage section for full cylinders, kept apart from the empties.
Cylinder in service
Cylinders connected to a manifold, regulator or process.
Defective cylinder
The holding spot for leaking or damaged cylinders waiting for return.
Acetylene
Acetylene cylinder storage, carts and welding bays.
Argon cylinder tag
Argon and argon-mix cylinder racks at welding stations and labs.
Propane exchange cage
Retail propane cylinder exchange cages at stores and gas stations.
Incompatible chemicals
Chemical rooms and shelves where products that react together must be kept apart.
Secondary containment
Tank dikes, spill pallets and containment berms with a drain valve.
WHMIS & GHS hazard signs
The GHS hazard pictograms in their red diamond, for chemical storage rooms, cabinets, tanks and dispensing points, plus the WHMIS reminders that go with them: SDS, workplace labels and the hazard statements for the products you keep on site.
GHS flammable
Rooms, cabinets and dispensing points that hold flammable gases, liquids, solids or aerosols.
GHS oxidizing materials
Storage for nitrates, peroxides, chlorates, pool chlorine and other oxidizers.
GHS explosive
Magazines and storage for explosives, self-reactive substances and unstable chemicals.
GHS gas under pressure
Cylinder cages, gas rooms and manifolds for compressed, liquefied and dissolved gases.
GHS acute toxicity, poison
Rooms and cabinets holding products that are fatal or toxic in small doses.
GHS health hazard
Areas using carcinogens, mutagens, sensitizers or products that damage organs over time.
GHS environmental hazard
Storage of pesticides, fuels and chemicals that harm fish and aquatic life if spilled.
Biohazardous infectious materials
Rooms, fridges and cabinets holding WHMIS biohazardous infectious materials.
Hazardous products storage area
Doors of rooms and cages where WHMIS hazardous products are stored.
Safety data sheets located here
Above the SDS binder or terminal so every worker can find an SDS fast.
Label all containers
Mixing, decanting and dispensing areas where products go into smaller containers.
Read the label and SDS
Chemical rooms, janitor closets and shop benches where workers pick up hazardous products.
Keep supplier labels on
Shelves and cabinet doors, a reminder never to remove or deface supplier labels, adhesive back.
Corrosives cabinet, acids
Acid cabinets, so acids stay apart from bases and oxidizers, adhesive back.
Oxidizers cabinet
Cabinets holding oxidizers, so nobody stores solvents or organics beside them, adhesive back.
Highly flammable liquid and vapour
Solvent rooms, tanks and drum stores holding Category 1 or 2 flammable liquids.
May damage fertility or the unborn child
Areas using reproductive toxins; tell workers who are or may become pregnant.
Respiratory sensitizer
Spray booths and process areas using isocyanates, enzymes, flour dust or other sensitizers.
Pyrophoric materials
Glove boxes, fume hoods and storage holding air-reactive metals and reagents.
Refrigerated gas, cryogenic burns
Liquid nitrogen, argon and CO2 dewars, bulk tanks and fill stations.
Simple asphyxiant
Rooms with nitrogen, argon, helium or CO2 that can push out the oxygen if they leak.
Biohazard, medical & oxygen
Biohazard, sharps, medical waste, oxygen in use, MRI and x-ray rooms, hand hygiene and isolation signs for hospitals, clinics, dental offices, long-term care and labs. Engraved plates take daily disinfectant wipe-downs without fading or peeling.
Biohazard, infectious materials
Doors, fridges and rooms where infectious materials are handled or kept.
Biomedical waste storage room
The locked room or cage where biomedical waste waits for pickup.
Sharps disposal
Above wall-mounted sharps containers in exam rooms, labs and washrooms, adhesive back.
Infectious waste bin
Lids and walls above infectious waste bins, so general garbage stays out.
Cytotoxic waste
Bins and storage for chemotherapy and other cytotoxic drug waste.
Medical gas zone valves
On or beside medical gas zone valve boxes in corridors.
MRI zone III, restricted access
The controlled entry to the MRI suite, before the control room.
No metal objects, MRI
At the zone III and zone IV doors, where metal must be left behind.
MR unsafe equipment tag
On carts, cylinders and equipment that must never enter the MRI room, adhesive back.
Pregnant? Tell the technologist
Imaging waiting rooms and change rooms.
Keep door closed during x-rays
Doors of x-ray, CT and dental imaging rooms.
Lead apron rack
Above the apron rack in x-ray rooms, so aprons are hung and not folded.
Contact precautions
Doors of patient rooms on contact precautions.
Droplet and contact precautions
Doors of patient rooms on droplet and contact precautions.
Airborne precautions
Doors of airborne isolation rooms.
Negative pressure room
Doors of negative pressure isolation rooms and anterooms.
Clean your hands, patient contact
Beside sinks and sanitizer dispensers at patient room doors and exam rooms.
Hand sanitizer station tag
Above wall-mounted sanitizer dispensers so they are easy to spot.
PPE donning area
The anteroom or station where staff put on PPE before entering an isolation room.
Clean utility room
Door plate for the clean supply and utility room.
Soiled utility room
Door plate for the soiled utility and hopper room.
Autoclave, hot steam
On or beside autoclaves and sterilizers in clinics, dental offices and labs.
Specimens only fridge
Fridges holding patient specimens, so food and medication go elsewhere, adhesive back.
Biohazard spill kit
Above the blood and body fluid spill kit.
Latex-free environment
Rooms and units kept free of latex for patients and staff with latex allergy.
Surgical attire required
Entrances to the operating room corridor and sterile core.
Hazardous drugs preparation area
Pharmacy clean rooms and areas where chemotherapy and other hazardous drugs are mixed.
Nuclear medicine hot lab
The door of the nuclear medicine hot lab, with the radiation warning symbol.
Cover your cough
Waiting rooms, reception desks and clinic entrances.
Labs, lasers & radiation
Containment-level biohazard doors, radiation signs for nuclear substance labs and gauge storage, laser signs by class, and the x-ray, MRI, cryogen, fume hood and lab PPE signs research and hospital labs post. Engraved plates hold up to disinfectant wipe-downs.
Biohazard, containment level 2
Every entry to a CL2 lab or animal room; post your emergency contact beside it.
Biohazard storage, risk group 2
Fridges, freezers and cabinets holding RG2 material outside the containment zone.
Lab fridge, no food or drink
Lab fridges and freezers, so nobody keeps lunch next to samples, adhesive back.
Nuclear substances lab
Every access point to a room where nuclear substances are used, with the radiation warning symbol.
Radioactive material storage
Doors of storage rooms, cabinets and shielded fridges that hold radioactive sources.
Portable nuclear gauge storage
Lockable rooms and cages where moisture-density gauges are kept between jobs.
X-ray in use when light is on
X-ray room doors in clinics, dental offices, vet hospitals and inspection labs, beside the warning light.
Pacemaker wearers keep out
Doors to MRI suites, NMR labs, induction heaters and large electromagnets.
Liquid nitrogen, oxygen deficiency
Rooms with liquid nitrogen dewars, cryostats and cryogenic freezers.
Fume hood, keep sash lowered
On the face of chemical fume hoods, adhesive back.
Lab coat and eye protection required
Lab entrances, so nobody walks in without a coat and glasses.
Chemical waste accumulation area
Benches, cabinets and hood bays where waste bottles are collected for pickup.
UV light hazard
Biosafety cabinets, transilluminators, UV curing stations and germicidal lamps.
Laser, class 2
On class 2 and 2M laser products and their enclosures, adhesive back.
Exposed high-power laser beam
Open-beam class 4 systems where the beam is exposed while the laser runs.
Laser protective eyewear required
Above laser lab doors and at the eyewear rack.
Class 2M laser
Equipment and benches with a Class 2M laser, where binoculars or lenses raise the risk.
Invisible laser radiation
Labs and enclosures with infrared or ultraviolet lasers you cannot see.
Radioactive waste
Radioactive waste containers and decay-storage shelves, with the radiation warning symbol.
X-ray equipment label
On analytical x-ray units, XRF analyzers and cabinet x-ray systems, adhesive back.
Fume hood, not for storage
On fume hood sashes, so bottles do not pile up and block the airflow, adhesive back.
Perchloric acid hood
Wash-down fume hoods reserved for perchloric acid work, adhesive back.
Food only fridge
Break room fridges and microwaves in lab buildings, adhesive back.
No flammables in this fridge
Ordinary lab fridges that are not rated for flammable storage, adhesive back.
Liquid nitrogen dewar tag
On LN2 dewars and fill stations, adhesive back.
Designated area, carcinogens in use
Benches, hoods and rooms set aside for work with carcinogens.
Biohazard, containment level 3
Entry to a CL3 lab suite; post your emergency contact beside it.
No mouth pipetting
Lab benches and doors, as a standing reminder to use a pipette aid.
Biosafety cabinet tag
On the face of biosafety cabinets, adhesive back.
Asbestos, lead & designated substances
Do-not-disturb tags for asbestos pipe insulation, ceilings and flooring, the signs a Type 3 removal needs at the enclosure and the decontamination facility, and work-area signs for lead, silica, mould and isocyanates. Engraved plates outlast the paper labels that fall off long before the asbestos is gone.
Asbestos insulation, do not disturb
Cable-tied to asbestos pipe, fitting, boiler and tank insulation so trades leave it alone.
Asbestos above ceiling
Ceiling access panels and T-bar grids with asbestos fireproofing or debris above the tiles.
Asbestos flooring
Door frames of rooms with asbestos floor tile, sheet flooring or mastic.
Asbestos work area, Type 3
Every entrance to a Type 3 removal enclosure, where Ontario requires signs warning of the asbestos dust hazard.
Asbestos abatement in progress
Corridor doors and hoarding outside an abatement area, to keep occupants and other trades out.
Decontamination facility
Entrance to the clean room of a Type 3 decontamination facility or decon trailer.
Lead work area
Lead paint removal, battery recycling, firing ranges and anywhere lead dust or fume is made.
Lead paint, do not sand or burn
Railings, trim and steel coated with lead-based paint, adhesive back.
Silica dust, tool tag
On concrete saws, core drills and grinders, so operators control the dust at the blade.
Mould remediation in progress
Containment entrances on mould clean-up jobs in homes, schools and offices.
Isocyanates in use
Spray foam jobs, auto body paint booths and anywhere two-part urethane coatings are sprayed.
Contains mercury
Thermostats, switches, manometers and lamp bins that hold mercury, adhesive back.
Vermiculite may contain asbestos
Attic hatches over loose-fill vermiculite insulation in houses and older buildings.
Asbestos survey on file
Service entrances and mechanical rooms, so contractors ask where the asbestos is before they drill.
Designated substances present
Site entrances and renovation areas where the owner's list of designated substances (Ontario Reg. 490/09) applies.
Asbestos waste container
Bins, drums and bags of asbestos waste waiting for disposal, adhesive back.
Air monitoring in progress
Beside air sampling pumps outside abatement enclosures.
Negative air unit
On HEPA negative air machines running an abatement enclosure.
No dry sweeping, silica
Concrete, masonry and stone shops and sites where silica dust settles.
Contains PCBs equipment tag
Transformers, capacitors and ballasts that still hold PCBs.
PCB storage site
Doors and fences of rooms or areas where PCB equipment and waste are stored.
Benzene, cancer hazard
Areas where benzene or high-benzene products are used, stored or sampled.
Ethylene oxide, cancer hazard
Sterilizer rooms and aeration areas that use ethylene oxide.
Slips, trips & low clearance
Wet floors, steps, ramps, uneven ground and low beams: the signs that head off the most common workplace injuries.
Wet floor
Washrooms, entrances, kitchens and wash-down areas, the everyday English-only plate.
Uneven surface
Patched floors, old slabs, yards and walkways with bumps, dips or heaved concrete.
Low beam, watch your head
Mounted on low structural beams, joists and bulkheads.
Low ceiling, watch your head
Basements, mezzanines, crawl-space entries and mechanical rooms with low headroom.
Low pipes, watch your head
Strapped to or below low pipe runs, ducts and cable trays in service corridors.
Low doorway, watch your head
Above short doorways in penthouses, tunnels, old buildings and equipment enclosures.
Oily floor
Machine shops, garages and press areas where oil and coolant reach the floor.
Icy floor, freezer area
Freezer doors, cold docks and blast-freezer aisles where frost forms on the floor.
Cleaning in progress
Hung at entrances and corridors while floors are being washed or stripped.
Mind the gap
Dock levellers, trailer edges, platforms and lifts with a gap between surfaces.
Cords and hoses on floor
Shops, stages, labs and job sites where cables and air hoses cross walkways.
Watch the curb
Building entrances, loading areas and parking lots with a curb people trip over.
Slip-resistant footwear required
Kitchens, wash-down rooms, food plants and other wet or greasy work areas.
Please wipe your feet
Entrance vestibules and mats, especially in winter slush and rain.
Raised threshold
Door frames with a raised sill, ramp edge or floor transition, two-hole tag.
Floor work in progress
Corridors and rooms closed while flooring is repaired, coated or replaced.
High step
Truck cabs, platforms, dock stairs and equipment where the first step is taller than usual.
Standing water
Parking garages, wash bays, loading docks and basements where water pools.
Keep stairs clear
Stairwells and landings, so nothing is stored or left where people walk.
Ice, water & outdoor hazards
Falling ice and snow, thin ice, deep water, no swimming and no diving, for roofs, ponds, yards and grounds.
Snow and ice may slide off roof
Walls below sloped and metal roofs, over walkways, doors and parking spaces.
Falling ice above, use other entrance
Doors closed for the winter because ice and icicles build up overhead.
Thin ice, keep off
Ponds, retention basins, rivers and quarry lakes on or beside your property.
Open water, ice may be unsafe
Near outfalls, aerators and springs where ice never forms properly.
No skating or walking on ice
Ponds, ditches and retention basins that people treat as rinks.
Snow removal in progress
Lot entrances, docks and walkways while plows and loaders are working.
Private pond
Ponds on private, farm, golf and industrial property.
No fishing
Private ponds, reservoirs, intakes and stormwater ponds.
Stormwater management pond
Around stormwater ponds at plants, subdivisions, condos and business parks.
Dangerous current
Riverbanks, spillways, culverts and outfalls with fast or hidden currents.
Water levels may rise suddenly
Below dams, weirs and control structures that can release water without warning.
No lifeguard on duty
Pools, beaches and docks at condos, hotels, camps and clubs.
Ice melt bin
Salt and sand bins at entrances, docks and stairs, two-hole tag.
Walkway not maintained in winter
Side paths, back stairs and secondary entrances that are not cleared of snow and ice.
Stay off snow piles
Parking lots, schoolyards and plazas where plowed snow is piled up.
Do not feed the wildlife
Ponds, picnic areas and lunch spots where feeding draws geese, gulls and pests.
Life ring
Posts and stations holding a life ring beside ponds, docks and pools.
No snowmobiles or ATVs
Gates, fields, trails and frozen ponds on private property.
Area subject to flooding
Low lots, underpasses, creek crossings and basements that flood in storms and spring melt.
No hunting
Fences, gates and tree lines around rural and industrial property.
PPE & mandatory signs
Tell people what to put on before they walk in: hard hats, eye, face and hearing protection, respirators, gloves, footwear, hi-vis, arc-rated and welding gear, plus PPE station and visitor tags. Blue plate, white letters, the mandatory-action colour.
Hard hats required
Entrances to construction zones, plant floors and anywhere with overhead work.
Respirator required
Spray booths, dusty processes and areas covered by a respiratory protection program.
High-visibility vest required
Yards, docks and any area shared with forklifts or vehicles.
PPE required, listed
Plant and site entrances, so everyone knows the minimum kit before they walk in.
Visitors must wear PPE
Reception and plant-floor doors where visitors and drivers come through.
Hearing protection, door strip
Above doors into loud rooms, where a long, low sign fits best.
PPE station
Above the rack or cabinet where hard hats, glasses and plugs are kept.
Inspect harness before use
Harness hooks and fall-protection storage.
Safety glasses at this machine
On the guard or control panel of grinders, lathes and saws, adhesive back.
Welding screen tag
On welding screen and curtain frames, so they get pulled closed before the arc is struck.
Arc-rated clothing required
Electrical rooms and switchgear lineups where energized work is done.
Cut-resistant gloves required
Glass, sheet metal and blade handling, and anywhere box cutters are used.
N95 respirator required
Dusty work, sanding and sweeping areas where a filtering facepiece is enough.
Eye and hearing protection, door strip
Above doors into shops and plant floors where both are required.
Visitor PPE station
Above the visitor rack or bin at reception and plant-floor doors.
Visitor safety glasses bin
On the bin or dispenser of loaner safety glasses, adhesive back.
No open-toed shoes
Shop, warehouse and lab entrances where sandals and open shoes are not allowed.
Protective clothing required
Entrances to chemical, dusty or contaminated areas where coveralls or suits are needed.
Earplugs available here
Above earplug dispensers at the entrance to noisy areas.
Prescription glasses are not safety glasses
Shop and plant entrances, so workers with regular glasses wear rated eyewear.
Bump cap required
Low-clearance areas such as crawl spaces, mezzanines and under conveyors.
Gloves and eye protection required
Shops, labs and handling areas where both hands and eyes are at risk.
Respirator storage
Cabinets and bins where personal respirators are kept between uses.
Heat-resistant gloves required
Ovens, kilns, furnaces, autoclaves and hot-forming stations.
Hard hat and hearing protection required
Entrances to mills, plants and production areas that are both noisy and overhead-hazard zones.
Metatarsal protection required
Steel, foundry, forging and heavy material handling areas.
Respirator users must be clean-shaven
Respirator stations and fit-test areas, since beards break the face seal.
Flame-resistant clothing required
Refineries, gas plants, foundries and hot work areas where flash fire is a risk.
Are you wearing your PPE?
Exits from change rooms and lunchrooms back onto the floor.
Machine safety
Guarding, pinch and crush, conveyor, robot cell, press, grinder and laser warnings for plant floors and shops, plus small tags that mount right on the guard or control station. Engraved plates hold up to oil, coolant and wash-down.
Pinch point, guard tag
Right on the guard or frame beside the pinch point, adhesive back.
Robot work area
Gates and fencing around industrial robot cells.
Lock out before clearing jams
Packaging lines, conveyors, shredders and anything that jams.
Authorized operators only
Forming presses, CNC machines, saws and anything that needs sign-off to run.
Do not bypass safety devices
Cells and machines with interlocks, light curtains or safety mats.
Flying debris
Chippers, shredders, grinders and saws that throw material from the discharge.
Pull-cord emergency stop
At the ends and along conveyors fitted with a pull-cord stop.
Interlocked guard
On interlocked doors and guards, so people know opening them stops the machine.
Rotating shaft, guard tag
On shaft guards and couplings over exposed rotating shafts, adhesive back.
Belt drive guard tag
On belt and pulley guards of motors, fans, compressors and pumps, adhesive back.
Chain drive guard tag
On chain and sprocket guards of conveyors and drives, adhesive back.
Two-hand control
At the two-hand control station of power presses, press brakes and riveters.
Light curtain, do not reach around
On light curtain posts at presses, robot cells and palletizers, adhesive back.
Robot cell entry rule
Gates and doors into robot cells, where people enter for maintenance and teaching.
CNC, close door before cycle start
On CNC mill and lathe control panels, adhesive back.
Grinder tool rest and tongue guard gaps
On bench and pedestal grinders; adjust with the wheel stopped as the wheel wears.
Bench grinder rules
Wall above bench and pedestal grinders in shops and maintenance areas.
Press rated capacity
On hydraulic shop presses and press brakes, with your press's rating.
Keep guard closed
On hinged guard doors that are not interlocked, adhesive back.
Hot melt glue
On hot melt units and glue guns on packaging and case-sealing lines, adhesive back.
Do not wear gloves at this machine
Drill presses, lathes, mills and other machines with rotating parts that can catch a glove.
Shear point tag
On guards and frames next to shearing edges and scissor linkages.
Test emergency stop before each shift
Beside the emergency stop on production lines and machines.
Unplug before changing blades
Saws, routers, grinders and other cord-connected tools and machines.
Do not oil, clean or adjust in motion
Machines with lubrication points or adjustments near moving parts.
Remove chuck key
On lathes and drill presses, where a chuck key left in becomes a projectile.
Clamp the work
On drill presses and mills.
Check guards before starting
At the operator station of machines with removable or adjustable guards.
High-pressure fluid injection hazard
Hydraulic power units, presses and mobile equipment with high-pressure hoses.
Never leave a running machine
Shop machines such as saws, lathes and grinders.
Stand clear when horn sounds
Conveyors and lines with a start-up warning horn or beacon.
Stop the machine before measuring
On lathes, mills and grinders, beside the controls.
Lockout & isolation
Numbered energy isolation points for your lockout procedures: electrical, pneumatic, hydraulic, steam, gas and stored energy, plus the stations and reminders around them.
Lockout point
Every isolation point in your procedure.
Energy isolation point
Numbered to match the written procedure.
Lock out before servicing
Machines and their disconnects.
Pneumatic isolation
Air supply valves.
Hydraulic isolation
Hydraulic power units.
Isolate all sources
Machines with electrical plus stored energy.
Main disconnect
The machine's main isolating switch.
Steam isolation
Steam supply valves named in the lockout procedure.
Gas isolation
Natural gas and propane valves on burners, ovens and heaters.
Not a lockout point
E-stops, selector switches and control devices people mistake for isolation points.
Group lockout box
Lock boxes that hold isolation keys during group lockout.
Lockout station
Above the board or cabinet that holds padlocks, hasps and tags.
Lockout procedure posted
Machine and panel doors where the written procedure is kept.
Verify zero energy
Machine start stations, as the last step before work begins.
Block raised parts
Presses, lifts, dump bodies and anything that can fall by gravity.
Electrical isolation point
Disconnects and breakers named in the lockout procedure, numbered to match it.
Valve lockout point
Water, chemical and process valves named in the lockout procedure.
Lockout board
A header strip above the board where a machine's locks, keys and tags hang.
Do not remove another's lock
At lockout stations and boards, as the one rule about personal locks.
Try-start point
At the start button or HMI used to prove zero energy after locking out.
Stored energy bleed point
Bleed and drain valves used to bring trapped air, hydraulic or spring energy to zero.
Gravity blocking point
Where the block, pin or prop goes to hold a raised part during lockout.
Isolation lock key tag
On each isolation lock's key before it goes into the group lockout box, numbered to its point.
Lockout/tagout required
On machines and equipment that must be locked out before anyone works on them.
Hazardous energy control program
Maintenance shops and plant entrances where the lockout program applies.
One person, one lock, one key
Above lockout stations and lock boards.
Worker inside, do not start
Hung on equipment, bins and enclosures while someone is working inside.
A tag alone is not a lockout
Lockout stations and tag dispensers.
Unplug and lock the plug
Cord-connected machines, where a plug lockout replaces the disconnect.
Lockout in six steps
Above lockout stations and in maintenance shops as a step-by-step reminder.
Disconnect located at
On equipment whose disconnect is out of sight, naming where to lock out; change the location to suit.
Chemical isolation point
Valves that isolate chemical lines, numbered to match your lockout procedure.
Mechanical isolation point
Pins, blocks and brakes that hold springs, flywheels or raised parts, numbered to your procedure.
Shift change, transfer locks
Lockout stations on jobs that run across shifts.
Confined spaces
Danger signs for hatches and manways, the entry rules that go beside them (permit, attendant, air testing, ventilation, rescue), and numbered tags that tie each tank, vault, pit or manhole to its hazard assessment.
Engulfment hazard, silos and bins
Access doors and roof hatches of silos, bins and hoppers where stored material can bury a worker.
Sewer gas, H2S and methane
Wet wells, lift stations, sewer chambers and sumps where hydrogen sulphide and methane collect.
Confined space, authorized entrants only
A long, low plate over hatches and doors to spaces entered under your confined space program.
Test the atmosphere before entry
At the entry point of every confined space, beside the permit board and gas monitor station.
Attendant required
Entry points where an attendant must stay outside the space for the whole entry.
Ventilate before and during entry
Tanks, vaults and pits that need forced-air ventilation for the whole entry.
Rescue plan required
Entry points and permit boards, so nobody goes in until the rescue plan, rescuers and gear are in place.
Lock out before entry
Tanks, vessels and pits with agitators, pumps, steam or process lines feeding them.
No entry without a gas monitor
Hatches and manways where every entrant must wear a personal gas monitor for the whole entry.
Harness and lifeline required
Manholes, tanks and other vertical entries where an entrant must be pulled out without anyone going in.
Assessed, not a confined space
Hatches, crawlspaces and pits a competent person has assessed and found not to be a confined space.
Entry permit posted here
Above the permit holder at the entry point, where the signed permit stays for the whole entry.
Numbered tank entry tag
On the manway of each tank in your confined space inventory, numbered to match its hazard assessment.
Numbered vault tag
On the hatch frame or nearest wall of meter, valve and electrical vaults.
Numbered boiler entry tag
Beside the manway or furnace access door of boilers that crews enter for inspection and cleaning.
Numbered manhole tag
On the frame, hatch or nearest post of each manhole and chamber in your inventory.
Numbered pit tag
At the edge or cover of press pits, sump pits and conveyor pits listed as confined spaces.
Confined space entry in progress
Set at the manway or hatch while an entry is under way.
Hazardous atmosphere
Tanks, vaults, sumps and pits where toxic or flammable gases can collect.
Breathing apparatus required for entry
Spaces where the entry plan calls for supplied air.
Nitrogen-purged vessel
Manways of vessels, reactors and tanks blanketed or purged with nitrogen.
Confined space rescue equipment
Above the cabinet or cage holding the tripod, winch and rescue gear.
Confined space below, keep hatch closed
Floor hatches and lids over pits, vaults and tanks.
Entrants sign in and out
At the entry point beside the entry log or permit board.
Check for entrants before closing
Inside hatch lids and on manway covers.
Tripod and winch inspection tag
On confined space tripods, davits and retrieval winches.
Fall protection, roofs & ladders
Numbered anchor and lifeline tags with their ratings, roof edge, skylight and hatch warnings, harness checks and the ladder rules people forget, for roofs, mezzanines, platforms and job sites.
Anchor tag, 1 worker 22 kN
On or beside each fall arrest anchor, numbered to match the anchor layout drawing; the dates change at each inspection.
Restraint-only anchor
Anchors rated for travel restraint only, so nobody clips a fall arrest lanyard to them.
Anchor out of service
On an anchor that failed inspection or is due for recertification, until a competent person clears it.
Horizontal lifeline, max workers
At each end of an engineered horizontal lifeline; change the ID, worker limit and clearance to match the design.
Davit base ID
On roof davit bases and sockets for suspended access, numbered to match the roof anchor drawing.
Skylight, do not step or lean
On skylight curbs and along roof walkways beside skylights and plastic light domes.
Guardrail removed, keep back
Hung on a chain or barrier where a guardrail section is down for loading or repairs, until it goes back up.
Roof warning line
Hung on roof warning lines and perimeter barriers that mark where fall protection starts.
Roof hatch, keep closed
On the underside of roof hatches and on the curb, so the opening is shut behind every trip.
Fixed ladder, use the safety system
At the foot of fixed ladders fitted with a rail or cable ladder safety system.
Stepladder, top two steps
Adhesive label for the side rail of stepladders, where the climber sees it.
Ladder ID, do not use if damaged
Adhesive ID for portable ladders, numbered to match your inspection log, so the rails are never drilled.
Mezzanine gate, keep closed
At pallet drop gates and removable rail sections on storage mezzanines and platforms.
Fall rescue kit
Above the cabinet or bag holding the rescue gear named in your fall rescue plan.
Harness inspection checklist
At harness storage and the crib where fall arrest gear is signed out.
Remove from service after a fall
At harness and lanyard storage, so gear that has stopped a fall is never hung back up.
Three-point contact
At the foot of fixed ladders, ship's ladders and equipment access ladders.
Roof anchors, tagged only
Inside the roof door or hatch, beside the posted anchor layout drawing.
Safety harness must be worn
At platforms, catwalks and roof access points where a harness is required, with the ISO harness symbol.
Working at heights training required
Site gates and roof access points on Ontario construction projects.
Boom lift, harness required
On boom lifts and at the rental or charging bay, so operators tie off in the basket.
Do not remove guardrail
On guardrails at mezzanines, pits, platforms and floor openings that trades take down for access.
Stay on roof walkway
At roof hatches and doors, so service people stay on the walkway pads and away from edges.
No unauthorized climbing, fixed ladder
On fixed ladders to roofs, tanks and towers that are kept behind a locked guard.
Ladder safety rules
At ladder storage racks and job site trailers.
Defective ladder, do not use
Hung on a damaged ladder until it is repaired or destroyed.
One person at a time on ladder
Adhesive plate on extension, step and fixed ladders.
Rolling ladder, lock wheels
On warehouse and stockroom rolling ladders.
Railing is not an anchor
On handrails and guardrails near roof edges and platforms where people are tempted to clip in.
Harness storage
Above hooks or cabinets where harnesses and lanyards are kept between uses.
Cranes, hoists & load limits
Rated capacity plates for bridge cranes, hoists, jibs, monorails and lifting devices, big enough to read from the floor, plus the load limits for floors, mezzanines, racking, shelves, elevators and dock levellers.
Crane capacity plate, 18 x 12
On both sides of a bridge crane so the rated load reads from the floor; change the load to match the crane.
Crane capacity, main and auxiliary hoist
Bridge cranes with two hoists, so the floor can read both rated loads.
Crane capacity strip, 12 x 4
Long and low for the web of a crane girder or gantry beam, readable from the floor.
Monorail capacity
On the monorail beam where the floor can read it, with the beam's rated load.
Hoist capacity tag
On the body or load block of chain and wire rope hoists, with the hoist's rated load.
Jib crane capacity
On the boom or mast of floor and wall mounted jib cranes.
Below-the-hook lifter tag
Riveted to lifting beams, spreader bars, plate clamps and other below-the-hook devices, with the rated load and the device's own weight.
Never stand under a suspended load
Crane bays, hoist areas and loading zones where loads travel overhead.
Trained crane operators only
At crane pendants, radio control stations and crane bay entrances.
Floor load limit
Storage rooms, upper floors and plant areas with a floor load rating from the structural engineer.
Mezzanine load limit
At the stair or gate of storage mezzanines, with the rating from the mezzanine drawings.
Shelf load limit
Adhesive label for steel shelving, cantilever arms and storage cabinets.
Rack bay load plaque
On the end frame of each rack run, with the loads from the rack supplier's drawings.
Elevator capacity plate
Inside passenger elevator cars near the car operating panel; change the load and persons to match the elevator.
Freight elevator, no passengers
Inside the car and at each landing of freight elevators not rated to carry passengers.
Dock leveller capacity
On the dock wall or leveller control box, with the capacity from the leveller's data plate.
Lift table capacity
On the base or control box of scissor lift tables and hydraulic work tables.
No side pulls
On hoist pendants and hoist bodies, so loads are always lifted straight up.
Crane in operation when light flashes
Under crane warning beacons at bay entrances and along the runway.
Lifting operations in progress
Portable barricade sign for the drop zone during crane and hoist lifts.
Crane swing radius
On the barricade around a mobile or tower crane's counterweight swing area.
Crane runway, authorized access
At ladders and catwalks leading up to the crane runway or bridge.
Material lift, no riders
At each landing of vertical material lifts and mezzanine freight lifts.
Use tag lines
In crane bays and laydown yards where loads are guided by hand.
Crane direction marker, north
On the runway wall, matching the direction buttons on the crane pendant, so the operator knows which way the bridge will travel.
Crane out of service tag
Hung on the pendant or disconnect while a crane or hoist is down for repair.
Damaged sling, do not use
Tagged on slings, chains and shackles pulled from service.
Do not lift people
On hoists, cranes and lifting attachments that are not rated to lift personnel.
Work platform capacity
On scissor lifts, work platforms and maintenance stands.
Lifting point
Beside lifting lugs and eyes on skids, tanks and equipment.
Construction sites
Gate, hoarding and site office signs, excavation, open hole and overhead work warnings, scaffold status tags, and the hot work, temporary power and dust rules a constructor posts on a job site.
Construction site, authorized personnel only
On site gates and hoarding, big enough to read from the street.
No unauthorized entry, gate
On hoarding doors, man gates and fence gates that must stay shut to the public.
Visitors report to the site office
At the site entrance, pointing visitors and new workers to sign-in and the site orientation.
Site office
On the door of the site trailer or field office.
Hard hat, boots and vest required
At site gates and building entrances, so everyone is in the minimum PPE before they walk on site.
Overhead work in progress
On barricades and entrances below scaffolds, roof work, steel erection and hoisting.
Hole cover, do not remove
Screwed to plywood or steel covers over floor openings, so nobody lifts one by mistake.
Scaffold tag, do not use
At the access point of a scaffold that is being built or altered, or has not passed inspection.
Scaffold tag, safe for use
At the access point once a competent person has inspected the finished scaffold.
Trades entrance
At the gate or door trades use, so workers stay out of the public or tenant entrance.
Delivery entrance
At the truck gate, so drivers find the right entrance and wait for a signaller.
Hot work area, fire watch
Where welding, cutting or grinding is under way, with an extinguisher and a fire watch on hand.
Temporary power panel
On temporary distribution panels and power stands on site; change the voltage to suit.
Crane operating overhead
At site entrances, walkways and laydown areas inside a tower or mobile crane's working radius.
Dust control area
Renovation zones in occupied buildings, at the barrier door and on the hoarding.
Danger construction zone, keep out
On hoarding, fencing and gates around an active construction zone.
Falling debris, keep clear
Below roofing, masonry and demolition work, and at building entrances under it.
Demolition in progress
At the entrances to areas being demolished, inside occupied buildings or on site.
Unsafe structure, keep out
On damaged or partly demolished buildings that nobody should enter.
Do not enter trench without support
At the edge of trenches during excavation and utility work.
Open elevator shaft
On barriers across elevator shaft openings at every floor during construction.
Blasting zone, turn off radios
On roads and paths into a blasting area, before the point where radios must be switched off.
Powder-actuated tools in use
Where fastening tools are being fired into steel or concrete.
Heavy equipment operating
At site entrances and laydown areas where excavators, loaders and lifts are moving.
Sidewalk closed, use other side
At both ends of a sidewalk closed by hoarding or site work.
Wet concrete, keep off
On barriers around fresh slabs, sidewalks and pads while the concrete cures.
Scaffold use with caution tag
Yellow status tag for a scaffold that has been modified or has restrictions on its use.
Shoring, do not remove
On shores and reshores under formwork and new slabs.
Construction site hours
At the site gate, showing the working hours allowed by the local noise bylaw.
Warehouse & traffic
Forklift and pedestrian traffic, loading docks, racking loads and aisle rules for warehouses, plants and distribution centres. Engraved plates that stand up to a busy floor.
Forklifts operating
At entrances to areas where forklifts and pedestrians share the floor.
Pedestrian walkway
At the start of marked pedestrian walkways through the warehouse.
Dock door number
Above each dock door, big enough to read from a truck cab.
Maximum rack load
On the end upright of each rack run, with the rated load per level.
Report rack damage
In racking aisles and at the shipping office.
Keep aisle clear
At aisle ends and in front of exits, panels and fire equipment.
Watch for trucks
On the yard side of dock doors and at pedestrian exits into the yard.
Stop, look both ways
Where walkways and doorways cross forklift aisles.
Sound horn
At blind corners, intersections and doorways on forklift routes.
Chock trailer wheels
Inside each dock door, at eye level for dock staff.
Aisle number
Hung at the end of each racking aisle.
Engage trailer restraint
Inside each dock door, beside the trailer restraint controls and signal lights.
No riders on forklifts
In forklift areas and at the charging station where operators start their shift.
Do not stand on forks
In storage and shipping areas where people may be tempted to ride the forks up to reach high stock.
Maximum stacking height
On walls and columns in floor-stacking areas, with the height your fire protection allows.
Pedestrian crossing
Where a marked walkway crosses a forklift aisle, facing the drivers.
One way
At the ends of one-way aisles and forklift routes, with the arrow turned the way traffic runs.
Keep 3 m from forklifts
Along forklift aisles and at picking areas where people work close to moving lift trucks.
No forklifts, hand trucks only
Mezzanines, office floors, ramps and freight elevators that forklifts must not use.
Look for forklifts before opening door
On the office or lunchroom side of doors that open onto a forklift aisle.
Pedestrians use walkway
At doors and aisle ends where people on foot must stay on the marked walkway, with the ISO walkway symbol.
Forklift operators wear seat belt
At forklift parking and charging bays, and on the overhead guard.
Forklifts stop and sound horn
Both sides of doorways and strip curtains that forklifts drive through.
Order picker, harness required
At order picker charging bays and on the machines themselves.
Authorized forklift operators only
At forklift parking, charging and key boxes.
Never stand under raised forks
Racking aisles, mezzanine pick-up points and dock areas where loads are raised overhead.
Blind corner, check mirror
Under convex safety mirrors at rack ends and blind corners.
Stay behind the yellow line
At dock doors, machines and pick-up points marked off with a floor line.
Drivers wait for green dock light
Outside, beside the dock communication lights, facing the truck driver.
Keep dock door closed
Inside each dock door, to keep the opening closed when no trailer is backed in.
Keep flue spaces clear
On rack ends in sprinklered warehouses, where product creeps into the gaps between loads.
Drivers waiting area
At the shipping office or driver lounge where truck drivers wait during loading.
Forklift pre-shift check
On the forklift or at the charging bay where the daily checklist hangs.
Forklift out of service tag
Hung on the steering wheel of a forklift that has failed its check.
Quarantine hold area
Above the racking or floor area set aside for product on hold.
Fire protection
Extinguisher, hose cabinet, sprinkler, standpipe and fire department connection signs, plus the riser, valve, drain and hydrant tags inspectors check. Red plate, white letters, so responders find them fast.
Fire extinguisher, wall strip
Above wall-mounted extinguishers, so they can be seen down a corridor.
Class K extinguisher
Above the Class K extinguisher in commercial kitchens with a hood suppression system.
Fire hose cabinet
On or above hose cabinets and hose stations.
Sprinkler control valve
Each sprinkler control valve, with the zone or area it serves.
Valve normally open
Sprinkler and standpipe valves that must stay open.
Inspector's test valve
The inspector's test connection on each sprinkler system or zone.
Sprinkler alarm bell
Under the exterior water-flow alarm bell, so passers-by know to call.
Standpipe hose valve
Standpipe hose valves in stairwells, with the stair and floor.
Main drain valve
The main drain on each sprinkler riser.
Fire alarm annunciator
Remote annunciator panels at the main entrance or fire department response point.
Fire department key box
Beside the exterior key box that holds building keys for responders.
Do not block fire equipment
Above extinguishers, hose cabinets and valves in storage areas and warehouses.
Spare sprinklers
On the spare sprinkler cabinet next to the riser.
Fire alarm pull station
Above manual pull stations that are hard to spot from down a corridor or across a plant floor.
Fire blanket
Above the fire blanket in kitchens, labs and welding bays.
Fire extinguisher inside
On closed extinguisher cabinets and cupboards, so the extinguisher is found without opening every door.
CO2 extinguisher, electrical fires
Above CO2 extinguishers in electrical rooms, server rooms and switchgear areas.
Sprinkler riser
On each sprinkler riser, with the system type and the floors it serves.
Alarm check valve
The alarm check valve on a wet sprinkler riser.
Dry pipe valve
The dry pipe valve serving loading docks, parking garages and other unheated areas.
Low point drain
Each low point (auxiliary) drain on a dry sprinkler system, so they are all found and drained before a freeze.
Post indicator valve
On or beside the post indicator valve that controls the underground supply to the sprinklers.
Notify fire department before closing
Sprinkler and standpipe control valves that must not be shut without telling the fire department.
Fire pump test header
Above the fire pump test header on the outside wall, so responders do not mistake it for the fire department connection.
Smoke control panel
Above the firefighters' smoke control panel at the central alarm and control facility.
Firefighters' elevator
At the ground-floor lobby of the elevator designated for firefighters' use.
Private hydrant number
Bolted to each private fire hydrant on a plant, campus or industrial park, numbered to match the site plan.
Fire extinguisher, symbol sign
Above extinguishers on walls and columns, with the ISO extinguisher symbol so it reads at a glance.
Fire hose, symbol sign
Above hose cabinets and hose reels, with the ISO fire hose symbol.
Fire alarm, symbol sign
Above manual pull stations so they can be found down a corridor or across a plant.
Fire blanket, symbol sign
Location sign above a wall-mounted fire blanket in kitchens, labs and shops.
Firefighting equipment
Fire points and cabinets that hold extinguishers, hose and other firefighting gear.
Fire door, do not prop open
Door strip for rated doors that keep getting wedged or hooked open.
Automatic fire door
Doors held open on magnetic hold-opens that release and close when the alarm sounds.
Sprinkler head clearance
Warehouse and storage room walls, where stock gets stacked up into the sprinkler heads.
Do not hang items from sprinklers
Near exposed sprinkler piping in shops, warehouses and parkades where people hang cords and signs.
Dry standpipe tag
On dry standpipe hose outlets in parking garages and unheated stairs.
Fire watch in progress
Posted at entrances while the alarm or sprinkler system is shut down and a fire watch is patrolling.
Sprinkler system out of service tag
Hung on the riser or control valve while the sprinkler system is impaired.
Class ABC extinguisher ID
Above or on the bracket of multipurpose dry chemical extinguishers.
Class A water extinguisher ID
Above pressurized water extinguishers, so nobody grabs one for an electrical or grease fire.
Class D extinguisher ID
Above dry powder extinguishers in machine shops that cut magnesium, titanium or other metals.
CO2 extinguishing system
At every entrance to rooms protected by a total-flooding carbon dioxide system.
Building is sprinklered
At the main entrance and fire department access point of a fully sprinklered building.
In case of fire, break glass
On glass-front cabinets for hose, extinguishers, keys or axes.
Fire separation, seal penetrations
On rated walls above the ceiling, so every trade firestops the holes they make.
Fire damper access tag
On ceiling and duct access doors in front of fire dampers that need regular inspection.
Smoke damper access tag
On ceiling and duct access doors in front of smoke dampers.
Exit & evacuation signs
Exits, evacuation routes, assembly points, areas of refuge and the stair and elevator signs the fire code asks for.
Exit, arrow right
Corridors and open floors where the way out is to the right.
Exit, arrow left
Corridors and open floors where the way out is to the left.
Exit, arrow straight ahead
Long corridors and warehouse aisles where the exit is straight on.
Exit, arrow down
Points to an exit down a stair or ramp, or to the door below the sign.
Exit, running figure right
Exit doors and routes leading to the right, with the ISO running-figure symbol.
Exit, running figure left
Exit doors and routes leading to the left, with the ISO running-figure symbol.
Emergency exit, arrow right
Directional strip along exit routes where the emergency exit is to the right.
Emergency exit, arrow left
Directional strip along exit routes where the emergency exit is to the left.
Fire exit, keep clear
On both sides of a fire exit door where carts, pallets or snow tend to pile up.
Fire exit, keep door closed
Door strip for self-closing exit doors that people wedge open.
Delayed egress door, 15 seconds
On exit doors with a delayed-release lock, at the push bar.
Exit route, keep clear
Corridors and stairwells that form part of the exit route, where storage creeps in.
Evacuation route, arrow straight ahead
Along evacuation routes where people should carry straight on.
Evacuation route, arrow down
At stair landings where the evacuation route continues down.
Emergency assembly point
On a post or wall at the outdoor spot where everyone gathers after an evacuation.
Assembly point, arrow right
Directional strip at building exits pointing the way to the assembly point.
Area of refuge, arrow right
Directional strip on floors with an area of refuge for people who cannot use the stairs.
Severe weather shelter area
Interior rooms or corridors picked as the tornado and severe weather shelter in the emergency plan.
Elevators out of service in a fire
At elevator call buttons on every floor, so people head for the stairs during an alarm.
Stair with roof access
At the top landing of the one stair that goes through to the roof.
No roof access
Strip on the top landing of stairs that do not go through to the roof.
Stair re-entry floor
Stair side of the doors that stay unlocked so people can get back onto the floor.
No re-entry from stair
Stair side of doors that lock from the stairwell, telling people where to keep going.
Exit at ground floor
Ground floor landing of a stair that carries on to the basement, so nobody walks past the way out.
Push bar to open
Above the panic hardware on exit doors.
Push to exit button
Beside the request-to-exit button on card-access and maglock doors.
Emergency door release
Next to the green release station on maglocked or access-controlled exit doors.
Emergency evacuation plan header
Header plate above the posted floor plan with exits and the assembly point.
Exit only, no entry
One-way doors that people may leave through but not come in by.
Accessible exit, arrow right
Points wheelchair users and others to the barrier-free exit route.
Evacuation chair
On the wall bracket or cabinet that holds a stair evacuation chair.
Emergency escape window
Basement, bedroom and portable classroom windows that serve as a second way out.
Fire escape
At the door or window that opens onto an exterior fire escape stair.
Escape hatch
Floor and roof hatches, tunnels and mezzanines where the hatch is the emergency way out.
Numbered exit door
Outside face of exit doors numbered to match the fire safety plan, so responders know which door is which.
Exit closed, use alternate exit
On an exit taken out of use during renovation, pointing people to the next one.
Exit signs circuit tag
On the breaker or switch that feeds the exit signs.
Emergency equipment & first aid
First aid, AEDs, eyewash and safety showers, emergency stops, shut-offs, generators and the plates that find them fast.
Fire alarm panel
Fire alarm control units.
Fire alarm circuit
At the fire alarm breaker.
Emergency shut off
Kitchen, boiler and process shut-offs.
Emergency generator
Standby generators.
Automatic transfer switch
Transfer switches with both sources named.
Fire pump disconnect
Fire pump service disconnects.
Gas shut off
Main gas valves.
Eyewash station
Eyewash and safety showers.
First aid
First aid kits and stations.
Emergency lighting
Emergency lighting circuits and panels.
Emergency power receptacle
On receptacles and devices fed from the standby generator, adhesive back.
AED location
Above the AED cabinet so it can be found from down the hall.
Eyewash and shower, wall sign
On the wall above combination eyewash and safety shower units.
Emergency stop location
On the wall or guard above a machine's emergency stop button.
Generator remote stop
At the remote emergency stop for a standby generator, outside its room or enclosure.
Transfer switch, two sources
On transfer switch doors where the switch can change sources on its own.
Fire department connection
Above the fire department (siamese) connection on the outside wall.
Emergency phone
Above emergency phones in plants, labs, parking garages and remote buildings.
Emergency exit
On exit doors and along exit routes, as a door sign alongside the lit exit signs.
Evacuation route, arrow right
Along corridors and plant aisles, pointing the way to the nearest exit.
Evacuation route, arrow left
Along corridors and plant aisles, pointing the way to the nearest exit.
Shelter in place area
Rooms set aside for people to gather during a chemical release, severe weather or a lockdown.
Area of refuge
At stair landings and protected areas where people who cannot use the stairs wait for help.
Emergency shower
On the wall above drench showers in labs, battery rooms and chemical areas.
AED inside
On the door of an AED cabinet or the cupboard that holds the defibrillator.
AED kept at reception
At entrances and lobbies when the AED is out of sight, so people know where to run for it.
Emergency contacts posted inside
On electrical room, mechanical room and panel doors with the emergency call list posted inside.
Emergency lighting test switch
Beside the key or test switch for battery-pack emergency lights and remote heads, adhesive back.
First aid room
Door strip for the first aid room in larger workplaces.
Defibrillator, symbol sign
Above the AED cabinet, with the ISO heart-and-bolt defibrillator symbol.
Emergency eyewash, with instructions
Above plumbed eyewash stations, with the ISO eyewash symbol and the rinse instruction.
Eyewash, arrow right
Directional strip in labs and plants pointing to the nearest eyewash.
Keep eyewash and shower clear
On the wall or floor area around eyewash and safety showers that keeps getting used for storage.
Emergency stretcher, symbol sign
Location sign above a wall-mounted stretcher or spine board.
Emergency call station, push for help
Above help-point intercoms in parking garages, elevator lobbies and campuses.
In an emergency call 911
Beside phones and at reception, with the internal number to call after 911.
Bleeding control kit
Above the cabinet holding tourniquets and trauma dressings, often next to the AED.
Burn kit
On the burn kit cabinet in kitchens, welding shops and labs.
Epinephrine auto-injector
On the cabinet or wall where the school or workplace keeps epinephrine auto-injectors.
Emergency fuel shut off
At the emergency stop for fuel dispensers at fleet yards, marinas and service stations.
Emergency gas shut off button
Beside the gas shut-off button in science labs and shop classrooms.
Emergency equipment cabinet
On cabinets of rescue gear, spill response or emergency supplies.
Emergency breathing apparatus
Above SCBA cabinets outside ammonia rooms, chemical areas and confined spaces.
Drench hose
Beside lab and battery-room drench hoses.
Emergency call, pull cord
Beside the emergency call pull cord in accessible washrooms and change rooms.
Electrical code & equipment
Service, disconnect, transformer and capacitor warnings, plus the conductor and fuse tags an inspector looks for. Danger and warning plates for hazards, black and white for equipment ID.
Main service disconnect
On the service entrance switch or main breaker, with the system voltage and rating.
Service disconnect location
Where the main disconnect is out of sight, so firefighters and electricians can find it.
Do not open under load
Isolating switches and bolted disconnects that are not rated to break load current.
Capacitor bank
Power factor correction and harmonic filter capacitor enclosures.
Transformer vault
Doors to transformer vaults and rooms with liquid-filled or dry-type units.
Keep 1 m clear, strip
A long, low strip above a row of panels or a switchboard line-up.
Voltage present
Covers and doors over terminals that stay live, adhesive back.
De-energize before servicing
Motor terminal boxes, control enclosures and luminaires that must be dead before work.
Exposed live parts
Inside dead-front doors and on barriers over bus that is live when the cover is off.
Utility CT cabinet
Current transformer and metering cabinets sealed by the utility.
Generator inlet
Beside a portable generator inlet with a breaker interlock.
Available fault current
Service equipment and switchboards, with the calculated value and the date it was worked out.
Replace fuses with
Inside fused switches, so the right class and rating goes back in.
Neutral
Neutral bars and neutral conductors in switchboards and splitters.
Grounding conductor
At the grounding electrode clamp and where the grounding conductor lands in the service.
Phase ID
Bus bars, feeders and terminations of phase A, in red to the CEC colour code (B black, C blue).
Series-rated combination
Panelboards and switchboards protected by a series-rated breaker combination, so only identical breakers go back in.
Service disconnect 1 of 2
Buildings with two service disconnects; order a 2 OF 2 plate for the other one.
Not a service disconnect
Building mains and sub-mains that look like service equipment but are fed from another disconnect.
Supplied by two services
At each service and on equipment fed from more than one utility service.
Customer-owned high voltage
Substations, switchgear and transformers on the owner's side of the utility demarcation.
Load side may be energized
Disconnects and breakers whose load conductors can be backfed by a generator, UPS, PV system or another feeder.
Bonding jumper, do not remove
Water pipe, gas pipe and main bonding jumpers, so they stay on through plumbing and meter work.
Ground rod test well
Above or on ground rod test wells, numbered to match the grounding drawing.
Electric heater, hot surface
Beside baseboard, unit and duct heaters that run hot enough to burn and must not be covered.
Shunt trip breaker
Breakers and switches with a shunt trip, so whoever finds one open checks the remote trip before resetting.
Maximum breaker or fuse size
Equipment and feeders, with the largest breaker or fuse the conductors and nameplate allow.
Utility meter location
At the service when the revenue meter is in another room, for meter readers and utility crews.
High voltage, authorized personnel only
Doors to switchgear rooms, vaults and fenced electrical yards, the most-ordered high voltage sign.
High voltage, do not touch
On enclosures, bus ducts and equipment that the public or other trades can reach.
Hazardous voltage, will shock, burn or cause death
Switchboards, transformers and control cabinets where the full consequence has to be spelled out.
Electric shock hazard, authorized personnel only
Electrical closets, control rooms and equipment enclosures that only trained staff should open.
Risk of electric shock, do not remove cover
Covers on control boxes, drives and power supplies that staff should never open.
Do not use water on electrical fires
Electrical rooms, switchgear and generator rooms, beside the extinguisher.
Live wires, keep away
Construction and renovation sites with energized temporary wiring or open boxes.
Buried high voltage cable
Marker posts and fences along underground primary feeders and duct banks on private property.
Low overhead wires
Yards, lanes and loading areas where trucks, booms and dump boxes pass under service drops or lines.
Transformer, keep clear
Dry-type transformers in electrical rooms and on mezzanines, where storage blocks the vents.
High voltage, do not climb
Substation fences, poles, towers and structures carrying overhead conductors.
Electrical panel, do not block
Above panels in storage rooms, garages and warehouses where stock and carts creep in front.
Electric heat tracing
On the insulation jacket of heat-traced pipes and vessels, so nobody cuts into a live cable.
Line terminals stay energized
Inside main breakers and service disconnects, where the line terminals stay live with the handle off.
No metal ladders
Electrical rooms, substations and work near overhead lines, so only non-conductive ladders are used.
Voltage plate, 120/208 V
Panels, enclosures and equipment covers on 120/208 V three-phase systems.
Voltage plate, 120/240 V
Residential and small commercial panels and equipment on single-phase 120/240 V service.
Voltage plate, 347/600 V
Switchboards, panels and enclosures on 347/600 V four-wire systems, the common Canadian commercial voltage.
Voltage sign, 13,800 V
Doors and fences of 13.8 kV switchgear rooms, substations and customer-owned primary equipment.
Voltage sign, 27,600 V
Doors and fences of 27.6 kV switchgear, transformer rooms and substations, common on Ontario distribution.
Voltage sign, 44,000 V
Fences and gates of 44 kV substations and customer-owned supply stations.
Do not hose down electrical equipment
Food plants and wash bays, on panels, starters and junction boxes in the washdown area.
High-resistance grounded system
Service switchboards and MCCs on high-resistance grounded systems, where a first ground fault does not trip.
Ungrounded system
Switchboards on ungrounded delta systems, so workers check the ground detector before starting.
Arc flash & shock
Warnings for switchboards, panelboards, MCCs and disconnects that may be examined or worked on while energized. Send your study data for full incident-energy labels.
Arc flash, panel size
Smaller panels and disconnects, adhesive back.
Arc flash boundary
Marks the arc flash boundary in front of switchgear and MCC line-ups.
Qualified persons only
Electrical room doors and switchgear aisles open only to qualified workers.
Arc flash, PPE category 2
Panelboards and MCCs assessed at PPE category 2 by the table method.
Energized work prohibited
Equipment the owner's electrical safety program says must never be worked on live.
Shock approach boundaries
Equipment from 151 to 750 V; change the distances to match your study.
Test before you touch
Panel covers and disconnects, as a reminder to test before contact.
Maintenance mode switch
Beside the energy-reducing maintenance switch on a breaker or switchboard.
Arc flash, incident energy
Study-result plate with the incident energy and working distance; we engrave the values from your study.
Arc flash boundary distance
Study-result plate with the arc flash boundary and nominal voltage for this piece of equipment.
Arc flash, PPE category 1
Panelboards and control panels assessed at PPE category 1 by the table method.
Arc flash, PPE category 3
MCCs and switchboards assessed at PPE category 3 by the table method.
Arc flash above 40 cal/cm²
Equipment where the study puts incident energy above 40 cal/cm², past the highest PPE category.
Do not operate with door open
MCC buckets, switchboard sections and disconnects that may only be switched with the door closed and latched.
Remote racking required
Draw-out breakers and starters that must be racked with a remote racking device from outside the boundary.
Arc flash study date
Beside the arc flash label, recording when the study was done and that it is redone after changes.
Energized work in progress
A reusable sign to hang at the barricade while permitted energized work is under way.
Arc-rated face shield and balaclava
Switchgear rooms and line-ups where the study calls for an arc-rated face shield and balaclava.
Arc-rated PPE required beyond this point
Entrances to switchgear rooms and MCC aisles where everyone past the door must wear arc-rated clothing.
Stand to the side when switching
Beside the handles of disconnects, breakers and MCC buckets, as a reminder to stand clear of the door line.
Infrared inspection window
Beside infrared windows on switchgear and MCCs, so thermography is done without opening covers.
Arc flash PPE station
Above the cabinet or wall rack that holds arc flash suits, hoods, face shields and voltage-rated gloves.
Limited approach boundary, strip
A long strip on the wall or barrier marking the limited approach boundary in front of exposed live parts.
Arc-resistant switchgear, keep doors latched
Arc-resistant switchgear and MCCs, which only protect the operator with every door and cover shut.
Voltage-rated gloves required
Panelboard rooms and test areas where work near exposed live parts calls for rubber insulating gloves.
Insulated tools required
Electrical rooms and tool cribs where only insulated, voltage-rated hand tools may be used near live parts.
Do not open while energized
Bolted covers and doors on switchboards and transformers that must never be opened live.
Switching in progress
A reusable sign for the switchgear room door or barricade while a switching procedure is under way.
Voltage indicator, unlit is not dead
Beside permanently mounted voltage indicator lights on disconnects and panels.
Panel & breaker ID
Panel names, voltage and phase, what feeds it and what it feeds. Black with white letters is the shop standard; any stocked pair works.
Panel ID with feed
Panelboard ID with voltage and source.
Main distribution panel
Main switchboards and distribution panels.
Panel ID tag
Simple panel name tags.
Voltage tag
Voltage and system identification.
Fed from
Source identification on downstream equipment.
Transformer
Dry-type transformers.
Disconnect switch
Safety switches and the load they serve.
Spare breaker
Spare positions in switchboards.
Junction box
Box covers, adhesive back.
Emergency panel
Panels on emergency power.
Meter ID
Multi-unit metering.
Ground bus
Ground bars and grounding points.
Tie breaker
Tie breakers in double-ended switchgear, with their normal position.
Main breaker
Main breaker position in a panelboard or switchboard.
Fused disconnect
Fused safety switches, with switch size, fuse size and class, and the load.
Splitter
Splitter troughs and tap boxes, with what leaves them.
Busway
Busway and bus duct runs, at the feed end and at each tap.
Surge protective device
Surge protective devices on switchboards and panelboards.
Heat trace panel
Heat tracing panels and their ground-fault protected circuits.
Feeder cable tag
Feeder cables in tray and pull boxes, tied on through the two holes.
Lighting panel
347/600 V lighting panelboards, with the system voltage and where the feeder comes from.
Power panel
120/208 V receptacle and equipment panelboards.
Distribution panel
Distribution panelboards and switchboards that feed other panels, with the rating and source.
Mechanical panel
600 V panels that feed pumps, fans, chillers and other mechanical equipment.
Sub-panel, fed from
Garage, basement and addition sub-panels, naming the breaker in the main panel that feeds them.
Panel location
In a suite or at the equipment, telling people where the panel that feeds it is.
Panel schedule inside door
On the panel cover, pointing to the circuit directory behind the door.
Isolation transformer
Shielded isolation transformers for sensitive and lab loads, with the rating and source.
Main lugs only
Panels without a main breaker, naming the upstream breaker that isolates them.
600 volts, panel cover
Covers and doors of 600 V panelboards, splitters and pull boxes.
Do not turn off, breaker tag
Beside breakers for freezers, alarms, servers and anything else that must stay on.
Fire alarm power source
On the fire alarm control panel, naming the panel and circuit that feed it and that the breaker is locked on.
Normal power tag
Receptacles, boxes and panels on utility power only, where emergency and normal circuits sit side by side.
Essential power tag
Receptacles, boxes and panels on the generator-backed essential system in health care and care homes.
Vital branch panel
Health care panels on the CSA Z32 essential electrical system; order DELAYED VITAL or CONDITIONAL to match.
Receptacle circuit tag
Small adhesive tag on receptacle plates and outlet boxes with the panel and circuit number.
GFCI protected tag
Downstream receptacles fed through a GFCI receptacle or breaker, so users know where to reset.
Isolated ground tag
Isolated ground receptacles and boxes for computers, medical and lab equipment, in the orange that matches the device.
Dedicated circuit tag
Receptacles for fridges, sump pumps, servers and appliances that must not share a circuit.
Space, no breaker
Panel positions with no breaker installed, kept apart from SPARE breakers that are in place but unused.
Two-section panel, section 1
Two-section panelboards with feed-through lugs; order SECTION 2 OF 2 for the other tub.
House panel
Multi-unit and plaza buildings, on the landlord's panel for corridors, exterior lights and shared loads.
Tenant unit panel
Suite and unit panels in condos, plazas and industrial units, with the meter that feeds them.
Standby power tag
Receptacles and panels on optional standby generator power, kept apart from life safety emergency circuits.
Motor control & equipment
MCC buckets, starters, VFDs, contactors, pumps, fans, control panels and the push-button and selector legends on them.
Motor control centre
MCC line-up nameplate.
MCC bucket
Each bucket door.
VFD
Drives and their motor.
Pump
Pumps, motors and skids.
Control panel
PLC and control enclosures.
Start / stop legend
Push-button legends.
Hand off auto
Selector switch legends.
Emergency stop
E-stop push buttons.
Compressor
Air and refrigeration compressors.
Air handler
Mechanical equipment ID.
Motor starter
Combination and magnetic starters, with the motor they run.
Soft starter
Soft starters on conveyors, pumps and fans.
Lighting contactor
Lighting contactors, with the circuits they switch and what controls them.
Elevator mainline disconnect
Elevator mainline disconnects in the machine room.
Drive / off / bypass legend
VFD bypass selector switches.
Local / off / remote legend
Selector switches that hand control between the panel and the BAS or PLC.
Reset legend
Reset push buttons on starters and control panels.
Conveyor control station
Local start/stop stations along a conveyor, named for the conveyor they run.
Compactor / baler
Waste compactors and cardboard balers, with the bucket or disconnect that feeds them.
Process pump
Process and transfer pumps, tagged to match the P&ID.
Compressed air dryer
Refrigerated and desiccant dryers on the compressed air system, next to the compressor tag.
PLC panel
PLC and I/O enclosures, naming the line they run and the source that keeps them powered.
VFD bypass
Bypass contactor panels and starters that run a drive's motor across the line.
Motor, 75 HP
Large motors, with the horsepower, voltage and the MCC bucket that starts them.
Crusher
Crushers and shredders in aggregate, recycling and mining plants.
Mixer
Mixers, agitators and blenders in food, chemical and batch plants.
Dust collector
Dust collectors and their fan motors, with the MCC bucket that feeds them.
Exhaust fan ID
On the exhaust fan housing or curb, matching the tag on the mechanical drawings.
Rooftop unit ID
Rooftop HVAC units, with the unit number, size and the zone it serves.
Elevator cab lighting disconnect
In the elevator machine room, on the separate disconnect for the cab lights and fan.
Elevator pit sump pump
On the sump pump controller or disconnect for an elevator pit.
Jockey pump ID
Jockey pump controller in the fire pump room, beside the main fire pump controller.
Sewage ejector ID
Sewage ejector and lift station control panels in basements and parkades.
Unit heater ID
Electric and hydronic unit heaters in warehouses, garages and stairwells.
Overhead door operator ID
On the motor operator or its disconnect for a dock or overhead door.
Off - on legend plate
Two-position selector switches on control panels and motor starters.
Open - close legend plate
Selectors and push buttons that drive dampers, valves and doors.
Power on legend plate
Under the pilot light that shows a control panel or starter has power.
Fault legend plate
Under the fault or overload pilot light on drives, starters and control panels.
Forward - off - reverse legend plate
Three-position selectors on reversing starters, hoists and conveyors.
Jog legend plate
Jog or inch push buttons on conveyors, presses and packaging machines.
Alarm silence legend plate
The push button that silences the horn on alarm and control panels.
Lamp test legend plate
The push button that lights every pilot lamp on a panel to check for burnt-out bulbs.
Speed legend plate
Above the speed potentiometer on a drive or control station.
Solar PV & storage
Disconnect, rapid shutdown, backfeed, multiple-source and battery storage labels for PV and energy storage systems, in the red-with-white-letters plates Section 64 work is specified in.
PV system disconnect
On or beside the PV disconnecting means.
PV AC disconnect
Inverter output disconnect.
PV DC disconnect
DC disconnect at the array or inverter.
Rapid shutdown switch
At the rapid shutdown initiator.
Dual power supply
Service panels with a PV interconnection.
Solar backfeed breaker
Inside the panel door, at the PV breaker.
PV combiner box
Combiner and junction boxes.
Inverter ID
Each inverter in the system.
Terminals energized both sides
PV disconnects that can be fed from both sides.
Main PV disconnect
The main PV disconnect on larger systems.
Energy storage system disconnect
On or beside the disconnecting means for a battery energy storage system.
Battery energy storage system
Walls, garages and rooms where an ESS is installed; change the chemistry and ratings to suit.
Rapid shutdown placard
At the service equipment of a building with a rapid shutdown PV system.
PV production meter
Generation and production meters on PV systems.
Utility-interactive inverter
Grid-tied inverters, with the unit number and output rating.
Photovoltaic power source, raceway
Along PV DC conduit and cable tray, at bends and where they pass through walls and floors.
DC conductors energized in daylight
Inverter rooms, combiner locations and roof access points on PV systems.
PV DC circuit ratings
At the PV DC disconnect, with the system's maximum voltage and current.
Utility, PV and storage sources
Service and distribution equipment fed by the utility, a PV system and an ESS.
Backup loads panel
Protected-loads panels supplied through a battery inverter.
Output limited, do not exceed
At the interconnection when the inverter output is limited in its settings to protect the panel bus or service.
Bipolar PV array
Inverters, combiners and disconnects on a bipolar PV array.
PV connectors, not under load
Combiners, junction boxes and inverters where PV connectors could be pulled apart while current flows.
PV load centre
Panels that collect inverter output circuits before the point of interconnection.
Microinverter AC combiner
AC combiner boxes for microinverter branch circuits, with the rated output current and voltage.
ESS emergency shutdown
At the emergency shutdown button or switch for a battery energy storage system.
Lithium-ion battery room
Doors to rooms and enclosures holding a lithium-ion energy storage system; change the energy rating to suit.
Utility PV disconnect
The lockable, visible-break disconnect the utility requires on a connected PV system.
Net meter
Bidirectional revenue meters on services with a connected PV system.
PV disconnect directory
A permanent plaque at the service showing where each PV disconnect is.
Solar PV array on roof
At the fire alarm panel, main entrance or roof hatch, so firefighters know the roof carries a PV array.
Rapid shutdown switch location
Where firefighters look first, pointing to a rapid shutdown switch that is out of sight.
Electric shock hazard, do not touch terminals
PV disconnects, combiners and inverters whose terminals can stay live from the array in daylight.
Rapid shutdown, outside array only
At the service on systems whose rapid shutdown de-energizes conductors outside the array but not the modules themselves.
Busbar fed by two sources
Panels where a PV backfed breaker shares the busbar with the utility main, to stop anyone overloading the bus.
PV point of connection
At the panel or disconnect where the inverter output connects, with the rated AC current and voltage.
Main breaker derated for PV
Panels where the main breaker was downsized to make room for a PV backfed breaker on the bus.
Supply-side PV connection
Services where the PV system is tapped ahead of the main, so turning the main off does not isolate it.
PV junction box
Rooftop and attic junction boxes on PV source and output circuits.
Stand-alone PV system
Cottages, cabins and remote sites powered by off-grid PV and batteries with no utility connection.
EV charging
Circuit, disconnect, metering and load-management labels for EV supply equipment in garages, condos and fleet yards.
EV charging station
Above the charger or parking stall.
EVSE disconnect
Disconnect for the EV supply equipment.
EV charger circuit
At the breaker or the charger.
Load management in use
Panels with an EV energy management system.
EV distribution panel
Dedicated EV distribution panels.
Charger stall number
Stall and pedestal numbers.
EV charging only
Walls and posts at charging stalls in garages and lots.
EV charger emergency shut off
At the emergency stop or shunt-trip button for chargers.
DC fast charger ID
Each DC fast charger cabinet, with its number and source.
EV sub-meter
Condo and rental EV sub-meters, matched to the suite and stall.
EVSE disconnect location
At chargers whose disconnect is out of sight in another room.
Bidirectional charger
Panels with a vehicle-to-home or vehicle-to-grid charger connected.
Return cable to holder
Shared chargers where cables left on the ground get driven over.
EV charger breaker
At each breaker in an EV panel, with the charger number and breaker size.
Load-managed EV circuit
Breakers and charger circuits whose current is controlled by an EV energy management system.
DC fast charger, 800 V DC
Inside and on the service doors of DC fast charger cabinets and power modules.
EVEMS, do not bypass
Services and EV panels sized on an EV energy management system, where bypassing it could overload the supply.
EV panel, fed from
EV charging panels, with the voltage and the breaker that feeds them.
EV charging, customers only
Retail and office charging stalls; we can engrave RESIDENTS ONLY or VISITORS ONLY instead.
Keep cable off the ground
On charger pedestals and walls where a cable left on the floor is a trip hazard and gets driven over.
EV charger disconnect
On the disconnect installed within sight of a charger, naming the charger it isolates.
Level 2 charger ID
On or above Level 2 chargers, so drivers know the charging rate.
Parking stall sub-meter
Above a condo or rental stall, naming the sub-meter that records its charging.
Electric vehicle parking only, tow-away
EV stalls in lots and garages where gas vehicles keep taking the charger spots.
EV charging, 2 hour limit
Shared chargers at workplaces, retail and municipal lots that limit how long a car can stay plugged in.
Move your vehicle when charged
At shared chargers in condo garages and workplaces, so stalls free up when charging is done.
EV-ready circuit
Roughed-in EV-ready outlets and junction boxes in new condo and townhouse parking, reserved for a future charger.
No extension cords or adapters
Beside EV chargers and EV receptacles in garages and parking structures.
Fleet EV charging only
Fleet yards and depots where chargers are reserved for company vehicles.
Charging in progress, do not unplug
On the charger pedestal or wall unit, so nobody pulls another driver's connector.
EVEMS controller ID
On the EV energy management system controller, naming what it monitors and controls.
Accessible EV charging
Accessible EV stalls with a wider access aisle and a reachable charger.
Data centres & UPS
A and B feeds, UPS, PDU, RPP, STS, ATS, EPO and bypass labels for white space, electrical rooms and battery rooms.
A feed
A-side PDUs, whips and breakers.
B feed
B-side PDUs, whips and breakers.
UPS
UPS modules.
PDU
Power distribution units.
Rack ID
Rack and cabinet ID.
Maintenance bypass
UPS maintenance bypass cabinets.
Battery cabinet
UPS battery cabinets and racks.
Rack transfer switch
Rack-mount transfer switches.
Emergency power off (EPO)
Beside or above the EPO station at the room exit.
CRAC / CRAH unit
On computer room air conditioners and air handlers, with their feed.
Static transfer switch
On static transfer switches, naming both sources.
Remote power panel, B side
On B-side remote power panels in the white space.
A feed panelboard
On A-side panelboards, with the UPS that feeds them.
UPS output breaker
At the UPS output breaker, naming the loads downstream.
Clean agent fire suppression
At the doors of rooms protected by a clean agent suppression system.
PDU, B feed
B-side power distribution units, red to match the B feed.
Hot aisle
At the end of a contained hot aisle, on the door or the containment frame.
Cold aisle
At the end of a contained cold aisle, on the door or the containment frame.
Busway tap box
Overhead busway tap-off boxes, with the busway, position, rack served and breaker.
Generator paralleling switchgear
Paralleling switchgear that synchronizes the standby generators onto one bus.
Battery string
Each UPS battery string on open racks, with its UPS and DC voltage.
UPS input breaker
At the UPS rectifier input breaker, naming the switchboard circuit that feeds it.
UPS bypass input breaker
At the UPS static bypass input breaker, naming its source.
Maintenance bypass breaker
The maintenance bypass breaker in a UPS bypass cabinet, with the rule for closing it.
Meet-me room
The door to the room where carriers and tenants cross-connect.
Telecom main grounding busbar
The main telecom ground bar in the entrance or equipment room.
CRAC unit
Compressor-based computer room air conditioners.
Rack PDU, A side
A-side rack power strips, blue to match the A feed, with the RPP circuit.
Rack PDU, B side
B-side rack power strips, red to match the B feed, with the RPP circuit.
White space rules
Doors into the data hall, with the house rules for the white space.
EPO, do not press except in emergency
Above or on the cover of the emergency power off button at the white space exit.
Open floor tile
A portable sign to stand at an open raised floor tile during cabling or maintenance.
Raised floor tile rules
At the white space door, so contractors lift tiles one at a time and put them back.
Data centre, authorized access only
Main entrance to the data hall, where badge holders must escort every visitor and contractor.
Suppression abort switch
Beside the abort switch for a clean agent system, at the exit of the protected room.
Clean agent manual release
Beside the manual release station for a clean agent suppression system.
UPS power only, receptacle tag
UPS-fed receptacles in offices, labs and network closets, to keep heaters and vacuums off the UPS.
No cardboard or packaging
Doors from the loading dock and staging room into the white space, to keep dust and fuel load out.
ESD protected area
Build rooms, repair benches and electronics labs where static discharge can damage equipment.
Fibre optic laser hazard
Fibre patch panels and optical cross-connects, where live fibre ends emit invisible laser light.
Rooms & doors
Door plates and access signs for electrical, mechanical, IT, boiler and elevator rooms, washrooms, stairs and roof hatches, plus occupancy and exit-door plates, so service crews find the right room and everyone else stays out.
Electrical room door plate
On the door of main and floor electrical rooms.
Electrical closet
On the door of a small floor or tenant electrical closet.
Mechanical room door plate
On the door of mechanical, HVAC and pump rooms.
IT / server room
On the door of server, network and IT equipment rooms.
Telephone room
On the door of telephone, telecom and demarcation rooms.
Generator room
On the door of rooms housing a standby generator.
Elevator machine room
On elevator machine room and control room doors.
Roof access
On roof hatches, roof doors and the ladders that lead to them.
Janitor room
On janitor and custodial closet doors.
Storage room
On storage room doors.
Sprinkler room
On the door of the sprinkler riser or valve room so firefighters find it fast.
Authorized personnel, door plate
A compact plate for service doors, hatches and gates.
Fire door, keep closed
On fire-rated doors in stairs, corridors and service rooms.
Keep door locked
On controlled doors that must stay locked when unattended.
Stair and floor ID
Inside the stairwell at each floor landing, beside the door.
Stair door plate
On the corridor side of each stairwell door, so people know which stair they are taking.
Stair and floor, landing plate
Inside the stairwell beside the door at each landing, when only the stair and floor are needed.
Maximum occupancy
At the entrance to assembly rooms, halls, cafeterias and restaurants, with the occupant load set for the room.
No exit
On doors that could be mistaken for an exit but lead to a storeroom, a dead end or a locked area.
Door to remain unlocked when occupied
Above or on main entrance doors fitted with a key-operated deadbolt.
Men's washroom
On the door of the men's washroom or change room.
Women's washroom
On the door of the women's washroom or change room.
All-gender washroom
On the door of a single-user or all-gender washroom.
Accessible washroom
On the door of the barrier-free or universal washroom.
Utility room
On the door of rooms holding the water heater, meters or service equipment.
Laundry room
On laundry room doors in condos, hotels, care homes and staff areas.
Garbage and recycling room
On the door of the garbage, recycling or chute room.
Maintenance shop
On the door of the maintenance or trades shop.
Office door plate
On general office doors; swap in a name or room number if you prefer.
Private door plate
On private offices and back rooms that visitors should not walk into.
Conference room
On the door of a conference room or boardroom.
Break room
On the staff break room door.
Lunch room
On the lunch room door in plants, shops and offices.
Staff kitchen
On the door of a staff kitchen or kitchenette.
Men's locker room
On the door of the men's locker or change room.
Women's locker room
On the door of the women's locker or change room.
Change room
On a shared or single-user change room door.
Shower room
On the door of staff showers in plants, gyms and offices.
Supply room
On the door of an office or janitorial supply room.
IT room
On the door of a small IT or network equipment room.
Data room
On the door of a data or network room that holds racks and switches.
Telecom room with number
On telecom room doors, numbered to match the drawings and cabling records.
Electrical room with number
On electrical room doors, numbered to match the single-line diagram and panel directories.
Mechanical room with number
On mechanical room doors, numbered to match the mechanical drawings.
Staff washroom
On washroom doors reserved for employees.
Family washroom
On single-room family washrooms in stores, arenas and public buildings.
Universal washroom
On the door of a universal (single-user, barrier-free) washroom.
Staff only door plate
On back-of-house doors in stores, restaurants and offices.
Push door plate
On the push side of a door, at hand height.
Pull door plate
On the pull side of a door, beside the handle.
This door must remain closed
On doors in fire separations and on doors that keep heat, noise or dust contained.
Please use other door
On the inactive leaf of a double door or a door that is kept locked.
Training room
On the door of a training or orientation room.
Copy room
On the copy and print room door.
Mail room
On the mail room door in offices and apartment buildings.
File room
On the door of a file or records room.
Wellness room
On the door of a wellness, quiet or nursing room.
Pump room
On the door of a domestic water or booster pump room.
Meter room
On the door of the room that holds the hydro, gas or water meters.
Compressor room
On the door of an air compressor room, with the hearing protection reminder.
Reception
Over a reception desk or on the door to the front office.
Security, surveillance & access
Video surveillance, no trespassing, guard dog, alarm and access-control signs, plus card readers, key cabinets and visitor rules.
Restricted area, ID badge required
Doors and gates into areas that only badged staff may enter.
Alarmed door
Rear, roof and secure-room doors on the security alarm that staff should not open in normal use.
Card access only
Beside the card or fob reader on staff-only doors.
One card, one person
Card-reader doors and turnstiles where staff might hold the door for someone behind them.
Do not prop door open
Card-access and secure doors that must close and latch behind everyone who uses them.
Security office door plate
On the door or window of the security office or guard desk.
Key cabinet
On the door of the building key cabinet or key safe.
Sign out all keys
On or beside the key cabinet, next to the key log.
No photography
Plant floors, labs and secure areas where cameras and phone photos are not allowed.
Shipping and receiving
On the wall at the shipping door, so drivers and couriers know where to check in.
Staff entrance
On employee entrances, to send visitors around to the front door.
Deliveries, ring bell
Beside the doorbell at a receiving or back door.
Access control panel
On access control and security panels in electrical and IT rooms, with the circuit that feeds them.
Security system circuit
At the breaker that feeds the alarm or access control system, adhesive back.
Premises under 24-hour video surveillance
At building entrances, gates and parking lots that are recorded around the clock.
CCTV cameras in operation
Beside entrances and in areas covered by closed-circuit cameras.
No trespassing, trespassers will be prosecuted
On fences, gates and yard entrances where you want the warning spelled out.
Premises protected by alarm system
On doors and windows of buildings with a monitored intrusion alarm.
Restricted area, authorized personnel only
At the entrance to restricted areas such as stockrooms, labs and control rooms.
ID badges must be visible
At staff entrances, turnstiles and inside secure areas.
All visitors must sign in
At the front entrance or reception of plants, offices and schools.
No loitering
On storefronts, entrances and loading areas.
Security checkpoint
At gatehouses and checkpoints where everyone stops to show ID.
Bags and parcels subject to search
At staff and visitor entrances of plants, warehouses and stores with a search policy.
No soliciting
On front doors and lobbies of offices and buildings.
No cash kept on premises
On site trailers, offices and storefronts to discourage break-ins.
Property patrolled by security
At lot entrances and on buildings covered by a security patrol.
Time-delay safe
On the door or counter of stores and gas stations that use a time-delay safe.
Use intercom for entry
Beside the intercom or call button at a locked entrance or gate.
Visitor entrance
Over the door visitors should use when staff come in elsewhere.
Visitor badge return
On the badge drop box at the reception desk or exit.
Key drop
On a key drop slot or box for after-hours key returns.
Video recorder ID tag
On the network video recorder so nobody unplugs it by mistake.
Parking, loading & traffic
Reserved, visitor and accessible parking, fire routes, loading zones, towing and speed plates for lots, docks and garages. Engraved plates that stay readable through salt, sun and snowplows.
Reserved parking
On posts or walls at the head of reserved stalls.
Reserved for manager
On the wall or curb stop at a stall held for a manager; we can engrave any title or name.
Reserved parking with unit number
At stalls assigned to a unit or suite in condos, plazas and industrial units.
Visitor parking
At the head of visitor stalls near the main entrance.
Customer parking only
In plaza and storefront lots where non-customers are towed.
Employee parking only
At the entrance to the staff lot or on posts at staff stalls.
No parking any time
Along drive aisles, doors and areas that must stay clear of parked cars.
No parking, fire route
Along the fire route at the building face; check your municipality's fire route bylaw for any required sign size.
Fire route, no stopping
On fire routes where even a quick stop blocks the trucks.
Loading zone
At curbside loading spots and short-term delivery bays.
No parking, loading area
In front of dock doors, ramps and loading bays.
Accessible parking, by permit only
At accessible stalls where a valid accessible parking permit must be displayed.
Van accessible tab
Under the accessible parking sign at the wider van-accessible stall.
15 minute parking
At short-stay stalls by the entrance of stores, clinics and offices.
Parking lot speed limit
At lot entrances and along private drives.
Speed bump ahead
Before speed bumps in lots, laneways and garages.
Stop (private lot)
At lot exits and private drive intersections where drivers must come to a stop.
Entrance only
At the inbound lane of a lot or garage with separate entry and exit lanes.
Drive-through
At the start of a drive-through lane, arrow pointing the way in.
Pick-up and drop-off
At the front curb of schools, clinics, daycares and offices.
Curbside pick-up
At stalls held for customers collecting online orders.
Parking stall number
On the wall or column at the head of a numbered stall.
Parkade space tag
Small level-and-space tag for condo and office parkade stalls.
Towing enforced
At lot entrances and on posts throughout lots with towing enforcement.
Driveway, keep clear
At driveways and laneways that must stay open for vehicles.
Compact cars only
On the wall or curb at short stalls in parkades.
Motorcycle parking
On the wall or post at motorcycle stalls.
Carpool parking
At preferred stalls held for staff who carpool.
Truck parking
At yard areas set aside for trucks and trailers.
No trucks
At lot entrances and drives that trucks cannot use.
Permit parking only
At lots and stalls limited to vehicles with a parking permit.
No overnight parking
At lot entrances where the lot must be empty overnight for snow clearing or security.
Head-in parking only
On walls or posts where vehicles must nose in, away from windows or air intakes.
Park at your own risk
At lot entrances and pay stations.
Private road, no through traffic
At the entrance to private roads, lanes and industrial park drives.
Boiler & refrigeration rooms
Refrigerant ID plates with safety group and charge, machinery room, leak alarm and emergency switch signs, and the boiler room warnings for relief valves, blowdown, steam and combustion air that refrigeration mechanics and boiler inspectors look for.
Refrigeration machinery room
On every door into a refrigeration machinery room.
Refrigerant ID, R-717 ammonia
On ammonia plants in arenas, cold storage and food plants; orange flags a toxic (B) refrigerant.
Refrigerant ID, R-744 CO2
On CO2 refrigeration racks in supermarkets and arenas, with the system charge in kilograms.
Refrigerant ID, R-134a
On chillers and other R-134a systems in the mechanical room.
Refrigerant ID, R-410A
On rooftop units, condensing units and split systems charged with R-410A.
Refrigerant ID, R-454B (A2L)
On rooftop and split systems charged with R-454B; yellow flags a lower-flammability A2L refrigerant.
Refrigerant leak alarm
Beside the refrigerant alarm horn and strobe inside the machinery room.
Emergency ventilation switch
On the switch outside the machinery room door that starts the exhaust fans in an emergency.
Refrigeration emergency shut off
On the emergency switch outside the machinery room door that stops the refrigeration equipment.
Boiler ID plate
On each boiler, numbered to match the drawings and the boiler log.
Combustion air opening
Beside combustion air louvres, grilles and ducts in boiler and furnace rooms.
Relief valve, do not plug
Hung on boiler, water heater and pressure vessel relief valves.
Steam, hot surfaces
In boiler rooms and along steam headers, traps and valves that are too hot to touch.
Low water cut-off test
Hung on the boiler's low water cut-off as a reminder to test it and log the result.
Boiler blowdown, hot discharge
At the blowdown valve, separator or drain where hot boiler water and steam discharge.
Gas-fired equipment, keep combustibles clear
In boiler, furnace and water heater rooms where storage creeps up on the appliances.
CO detector
Below the carbon monoxide detector in a boiler or furnace room, so no one covers or unplugs it.
Mechanical room, keep door closed
On mechanical, boiler and machinery room doors that must close behind everyone.
Hot pipes, do not touch
On uninsulated heating, steam and hot water piping within reach.
Do not vent refrigerant
On refrigeration and air conditioning equipment and in machinery rooms.
Refrigerant oxygen displacement hazard
At the door of refrigeration machinery rooms and basements with large refrigerant charges.
Authorized boiler operators only
On boiler control panels and the boiler room door where only certified operators may adjust the plant.
Chiller ID plate
On the chiller so service techs can match it to the drawings and refrigerant log.
Condensing unit ID plate
On rooftop and grade-mounted condensing units.
Expansion tank ID plate
On hydronic expansion tanks in the boiler room.
Heat exchanger ID plate
On plate and shell-and-tube heat exchangers.
Make-up air unit ID plate
On make-up air units for kitchens, shops and parkades.
Fresh air intake
Beside outdoor air intakes at grade or on the roof.
Gas, water & HVAC shut-offs
Main water and gas shut-offs, meters, backflow preventers, boilers, rooftop units and pumps, labelled so a tenant, a plumber or a firefighter can isolate them in a hurry.
Main water shut off
At the main water valve where the service enters the building.
Main gas shut off
At the main gas valve inside or beside the meter set.
Gas shut off below
On the wall above a gas valve that sits low or behind equipment.
Water shut off behind panel
On access panels and doors that hide a water shut-off valve.
Gas meter
At gas meters, numbered for multi-unit buildings.
Water meter
At the water meter and its isolation valves.
Backflow preventer
On backflow prevention assemblies, named to match the test records.
Hot water tank
On domestic hot water tanks and heaters.
Boiler emergency shut off
At the boiler emergency switch beside the boiler room exit door.
Rooftop unit disconnect
On the disconnect switch beside each rooftop unit.
Air handler disconnect
On the disconnect for an air handling unit.
Cooling tower
On cooling towers and their local disconnects.
Sump pump
At the sump pump breaker, receptacle or control panel.
Gas valve tag
Hung on branch gas valves, naming what each one isolates.
Water valve tag
Hung on branch water valves, naming what each one isolates.
Furnace switch
On the furnace or boiler service switch, adhesive back.
Reclaimed water, do not drink
At hose bibs, wash-down taps and other outlets fed by a reclaimed, rain or grey water system.
Gas meter, keep clear
Beside gas meter sets that get buried in snow or blocked by storage and parked cars.
Fuel oil tank
On fuel oil tanks for boilers, furnaces and generators, with the capacity and what the tank feeds.
Irrigation shut off
At the irrigation isolation valve inside the building, as the fall reminder to shut down before frost.
Sanitary cleanout
At sanitary drain cleanouts in floors, walls and ceilings, so plumbers open the right line.
Storm cleanout
At storm and roof drain cleanouts, so no one mistakes them for the sanitary line.
Catch basin, no dumping
Beside catch basins, trench drains and yard drains that run straight to the storm sewer.
Backflow test due
On or beside backflow preventers that must be tested every year; set the month to your test cycle.
Main water entry
Where the municipal water service enters the building, usually beside the meter and main shut-off.
Gas shut-off behind access panel
On the access panel or ceiling hatch that hides a gas shut-off valve.
Propane shut-off
At the propane shut-off valve for heaters, kitchens and generators.
Fuel oil shut-off
At the fuel oil shut-off valve between the tank and the burner.
Emergency fuel shut-off
At the emergency fuel valve or switch for a diesel generator or fuel-fired plant.
Main electrical shut-off
On the main switch or the door of the room that holds it, so firefighters and trades can find it.
Sprinkler shut-off valve inside
On the closet or room door where the sprinkler shut-off valve is kept.
Outside tap shut-off
On the indoor shut-off for an outside tap or hose bib.
Backwater valve
Beside the backwater valve access cover on the sanitary drain.
Gas pressure regulator tag
On gas pressure regulators downstream of the meter.
Water softener tag
On the water softener or treatment unit on the domestic water line.
Pipe markers
Pipe ID plates in the standard colour code: red for fire protection, green for water, blue for air and inert gas, yellow for steam, gas and fuel, orange for chemicals, brown for oils and purple for reclaimed water. Strap them to the pipe or stick them to the insulation jacket.
Fire sprinkler pipe marker
On sprinkler mains and cross mains, at valves, branches and wall penetrations.
Standpipe pipe marker
On standpipe risers and the piping to hose valves in stairwells.
Fire pump discharge pipe marker
On the fire pump discharge and test header piping in the pump room.
Domestic cold water pipe marker
On domestic cold water mains and risers, near valves, branches and wall penetrations.
Domestic hot water pipe marker
On domestic hot water supply piping from the heater to the fixtures.
Hot water recirculation pipe marker
On the small return line that circulates domestic hot water back to the heater.
Chilled water supply pipe marker
On chilled water supply mains; choose the left or right arrow to match the flow.
Chilled water return pipe marker
On chilled water return mains; choose the left or right arrow to match the flow.
Heating water supply pipe marker
On heating water supply mains from the boilers; choose the arrow that matches the flow.
Heating water return pipe marker
On heating water return mains back to the boilers; choose the arrow that matches the flow.
Condenser water pipe marker
On condenser water piping between the chillers and the cooling tower.
Boiler feed water pipe marker
On feed water piping from the feed tank or deaerator to the boilers.
Glycol supply pipe marker
On glycol heating, cooling and snow-melt loops.
Compressed air pipe marker
On compressed air mains and drops, showing the system pressure.
Nitrogen pipe marker
On nitrogen supply lines in plants, labs and refrigeration shops.
Low pressure steam pipe marker
On the insulation jacket of steam mains and branches, showing the pressure class.
Condensate return pipe marker
On condensate return lines from steam traps and receivers back to the boiler room.
Natural gas pipe marker
On natural gas piping inside buildings, showing the operating pressure.
Propane pipe marker
On propane piping from the tank or cylinder manifold to the appliances.
Fuel oil supply pipe marker
On fuel oil lines between the tank, the transfer pump and the burner or generator.
Sodium hypochlorite pipe marker
On chemical feed lines in pool, water treatment and cooling tower chemical rooms.
Lube oil pipe marker
On lube oil lines on compressors, turbines and gearboxes.
Hydraulic oil pipe marker
On hydraulic lines on presses, lifts and hydraulic power units.
Reclaimed water pipe marker
On reclaimed, rain and grey water piping, so no one ties a drinking water line into it.
Potable water pipe marker
On drinking water lines, to keep them clearly apart from process and non-potable water.
Non-potable water pipe marker
On process, raw and cooling water lines that are not safe to drink.
Fire protection water pipe marker
On fire service mains and fire protection water piping.
Sanitary drain pipe marker
On sanitary drain and waste piping in ceilings and service rooms.
Storm drain pipe marker
On roof drain and storm piping inside the building.
Sanitary vent pipe marker
On plumbing vent stacks and vent headers.
High pressure steam pipe marker
On high pressure steam mains; add the operating pressure if you like.
Medium pressure steam pipe marker
On medium pressure steam mains between the boiler plant and the users.
Instrument air pipe marker
On dry instrument air headers that feed controls and valve actuators.
Vacuum pipe marker
On process and lab vacuum lines.
Oxygen pipe marker (industrial)
On industrial oxygen lines in welding shops and process plants.
Argon pipe marker
On argon and shielding gas lines in welding and fabrication shops.
Glycol return pipe marker
On glycol return piping, paired with the glycol supply marker.
Fuel oil return pipe marker
On fuel oil return lines from the burner or generator back to the tank.
Condensate drain pipe marker
On air conditioning and furnace condensate drain lines.
Medical oxygen pipe marker
On medical oxygen pipelines in hospitals, clinics and long-term care, in the green used for oxygen in Canada.
Medical air pipe marker
On medical air pipelines; black and white is the Canadian colour for medical air.
Medical vacuum pipe marker
On medical vacuum (suction) pipelines in hospitals and clinics.
Nitrous oxide pipe marker
On nitrous oxide pipelines in hospitals and dental offices.
Softened water pipe marker
On softened water lines from the softener to boilers, kitchens and laundries.
Sodium hydroxide pipe marker
On caustic feed lines in water treatment and process plants.
Kitchens & food safety
Hand sink, prep sink and three-compartment sink plates, walk-in and holding temperature reminders, and the hood suppression, gas shut-off and hot oil signs a commercial kitchen needs. Engraved plates that shrug off steam, grease and daily sanitizer.
Hand washing sink only
Above every hand washing sink in food preparation and dish areas.
Food prep sink only
Above sinks kept for washing produce and thawing food.
Three-compartment sink, wash
Above the first compartment of a manual dishwashing sink; order with the rinse and sanitize plates.
Three-compartment sink, rinse
Above the second compartment of a manual dishwashing sink.
Three-compartment sink, sanitize
Above the third compartment of a manual dishwashing sink, where dishes soak in sanitizer.
Mop sink
Above the janitor's mop sink so it never doubles as a hand or food sink.
Walk-in cooler, keep door closed
On the outside of walk-in cooler doors.
Walk-in freezer inside release
Inside walk-in freezers and coolers, beside the door release knob, so no one is ever trapped.
Hair nets required
At the entrance to kitchens, bakeries and food production floors.
Kitchen staff only
On kitchen swing doors and back-of-house corridors.
Hot oil, deep fryer
On the wall beside deep fryers, where splashed water or ice makes hot oil erupt.
Kitchen fire suppression pull station
Above the manual pull station for the hood fire suppression system, on the way out of the kitchen.
Kitchen gas shut off
Above the manual gas valve that feeds the cooking line.
Cold holding, 4 °C or colder
On reach-in coolers, walk-ins and cold wells holding hazardous food.
Hot holding, 60 °C or hotter
On steam tables, hot wells and holding cabinets.
Raw meat, bottom shelf
On the bottom shelf of walk-ins and reach-ins, below ready-to-eat food.
Sanitize hands before entering
At sanitizer stations at the door of food production areas.
Allergen storage
On shelves and bins that hold nuts, sesame, gluten and other priority allergens.
Food allergy, tell your server
At the counter or host stand of restaurants and cafeterias.
No jewellery or watches
At the entrance to food production and packaging floors.
Beard nets required
At the entrance to kitchens, bakeries and food plants.
Walk-in freezer
On the door of a walk-in freezer.
Check and record temperatures
Beside coolers and freezers where staff fill in the temperature log.
Thaw safely
In prep areas and on walk-in doors where frozen food is thawed.
Cool hot food fast
Near the blast chiller or walk-in where cooked food is cooled down.
Reheat to 74 °C
At steam tables and reheating stations.
Label and date all food
In walk-ins, dry storage and on prep line coolers.
Store chemicals away from food
On the chemical shelf or cabinet in kitchens and food plants.
Ice scoop only
On the front of ice machines and ice bins.
Grease interceptor
Beside the grease interceptor or trap access in commercial kitchens.
Waste, recycling & spills
Hazardous waste, used oil, batteries, recycling and spill kit signs for storage areas and bins, so every drum and bin gets the right waste and a spill gets cleaned up fast.
Hazardous waste storage area
At the entrance to a hazardous waste storage room, cage or yard area.
Hazardous waste container tag
On drums, pails and totes that collect hazardous waste.
Used oil filters
On the drum or bin that collects used oil filters.
Used antifreeze
On the drum or tank that collects used antifreeze and coolant.
Used cooking oil
On the used fryer oil bin or tank behind restaurants.
Used batteries for recycling
On battery collection bins in offices, stores and shops.
Used lead-acid batteries
At the storage spot for spent vehicle, forklift and UPS batteries.
E-waste recycling
On bins and cages that collect old computers, cables and electronics.
Recycling bin
On recycling bins and the wall above them.
Garbage bin
On garbage bins and dumpsters next to recycling.
Cardboard only
On cardboard bins, balers and dumpsters.
Organics bin
On organics and food waste bins in kitchens, lunch rooms and loading docks.
Scrap metal only
On scrap metal bins in shops, plants and job sites.
Wood waste only
On wood waste bins on job sites and in shops.
Spill kit inside
On the cabinet, drum or bin that holds a spill kit.
Spill response station
Above the spill station in shops, warehouses and chemical areas.
Oil-only spill kit
On spill kits stocked with oil-only absorbents for fuel and oil spills, including outdoors.
Empty aerosol cans
On the container that collects empty aerosol cans.
Fluorescent lamp recycling
On boxes and racks that collect spent fluorescent tubes and CFLs.
Empty drum storage
At the area where empty drums wait for pickup or reconditioning.
Non-hazardous waste
On bins and drums for non-hazardous process or general waste.
Only rain down the drain
Beside catch basins and floor drains that lead to the storm sewer.
Oily rags only
On the self-closing waste can for oily and solvent-soaked rags.
Waste solvent
On drums and safety cans that collect spent solvent.
Broken glass only
On broken glass boxes in labs, kitchens and bars.
Containment drain valve
On the drain valve of a dike or spill containment area.
Private bin, no dumping
On dumpsters and bin enclosures that outsiders keep filling.
Bilingual English / French
Safety and room signs with English and Canadian French on the same plate, for Quebec sites, federal buildings and any workplace that signs in both official languages.
Shock hazard / Risque de choc électrique
Enclosures, control panels and live-front equipment.
Arc flash / Arc électrique
Panelboards, switchboards and MCCs that may be worked on while energized.
Lock out / Cadenasser
Machines and their disconnects, under your lockout program.
Multiple sources / Sources multiples
Equipment fed by utility plus generator, PV or a second feeder.
Hearing protection / Protection auditive
Compressor rooms, generator rooms and noisy plant floors.
First aid / Premiers soins
First aid kits and first aid rooms.
Eyewash / Douche oculaire
Eyewash stations and safety showers.
Emergency shut off / Coupure d'urgence
Kitchen, boiler and process emergency shut-offs.
Emergency stop / Arrêt d'urgence
Legend plate under an e-stop push button, adhesive back.
Confined space / Espace clos
Tanks, vaults, pits and manholes.
High voltage, keep out / Défense d'entrer
Fences, gates and vault doors around substations and equipment over 750 V.
Chemical storage / Produits chimiques
Doors of chemical storage rooms, cabinets and cages.
Slippery floor / Plancher glissant
Tiled entrances, wash bays, ramps and floors that are always slippery.
Watch your step / Attention à la marche
Single steps, step-downs and uneven floors, on a long strip at eye level.
PPE required / ÉPI obligatoire
Plant and shop entrances where hard hats, safety glasses and hearing protection are all required.
Keep door closed / Garder la porte fermée
Service room, stairwell and cold room doors, on a strip at eye level.
No entry / Entrée interdite
Doors, gates and corridors no one may pass, with the no-entry symbol.
Authorized personnel only, door strip
A long two-hole strip across the top of a restricted door.
Lockout point / Point de cadenassage
Each isolation point, numbered to match the written lockout procedure.
Fire extinguisher / Extincteur
Above wall-mounted extinguishers, so they can be found from down the corridor.
Fire alarm / Alarme incendie
Above manual pull stations, or where one is hidden behind a column or door.
Emergency exit / Sortie de secours
Exit doors and exit routes, alongside the lit running-man exit signs.
Muster point / Point de rassemblement
Outdoor assembly areas, on a post or wall where everyone gathers after an evacuation.
Not an exit / Ceci n'est pas une sortie
Doors that look like a way out but lead to a dead end, storage or a hazard.
Emergency exit only, alarm will sound / Sortie de secours seulement
Alarmed exit doors that are not for everyday use.
Do not block exit / Ne pas obstruer la sortie
On or beside exit doors where carts, stock or furniture tend to collect.
Evacuation route / Voie d'évacuation
Directional sign along evacuation routes, arrow pointing right.
Area of refuge / Aire de refuge
At the area of refuge where people who cannot use the stairs wait for help.
In case of fire do not use elevator / En cas d'incendie
At elevator call buttons on every floor.
Fire door, keep closed / Porte coupe-feu
On rated doors in stairwells, corridors and service rooms.
Fire equipment, do not block / Équipement d'incendie
Below extinguishers, hose cabinets and pull stations where stock gets piled in front.
First aid kit / Trousse de premiers soins
On first aid kits and the cabinets that hold them.
Emergency shower / Douche d'urgence
Above safety showers in labs, battery rooms and chemical areas.
Safety footwear required / Chaussures de sécurité
Plant, warehouse and site entrances where safety footwear is required.
Protective gloves required / Gants de protection
Machines, chemical areas and handling stations where gloves are required.
Respirator required / Protection respiratoire
Spray booths, dusty processes and chemical areas where respirators are required.
High-visibility vest required / Dossard haute visibilité
Docks, yards and sites with vehicle or forklift traffic.
Face shield required / Écran facial
Grinders, chemical pouring and other tasks that need a face shield.
Fall protection required / Protection contre les chutes
Roof access, platforms and edges where a harness and lanyard are required.
No smoking or vaping / Ne pas fumer ni vapoter
Entrances, offices and work areas where both smoking and vaping are banned.
No cell phones / Cellulaires interdits
Fuel, blasting, lab and production areas where phones are not allowed.
No food or drink / Aucune nourriture ni boisson
Labs, server rooms, clean areas and chemical handling areas.
Danger keep out / Défense d'entrer
Doors, gates and barriers to any hazardous area that must stay closed to the public and staff.
Danger corrosive / Corrosif
Acid and caustic storage, battery rooms and chemical dispensing points.
Caution construction area / Chantier de construction
Hoarding, gates and renovation areas inside occupied buildings.
Electrical panel, keep clear / Panneau électrique
On or beside panelboards where the working space in front gets used for storage.
Employees only / Réservé aux employés
Back-of-house doors in stores, restaurants and offices.
Keep door locked / Garder la porte verrouillée
Electrical, server, chemical and storage rooms that must stay locked.
Visitors report to reception / Visiteurs
Main entrances, gates and lobbies where visitors must sign in.
Video surveillance / Surveillance vidéo
Entrances, lots and work areas covered by security cameras.
Mechanical room / Salle mécanique
Door strip for mechanical rooms in buildings that sign in both languages.
Push / Poussez door plate
On the push side of doors.
Pull / Tirez door plate
On the pull side of doors.
No signs match that
Build it from scratch in the sign maker, or send the wording through the quote form and we'll draw it for you.
References name the standard the wording usually comes from. Your inspector (the authority having jurisdiction) has the final say on wording, size and colour, so check the drawings or spec before you order.
Common questions
Still unsure? Call 289-275-9572 or send your list through the quote form. Read the caution label guide for wording, codes, and materials.
Where can I order custom yellow CAUTION signs with my wording?
For Canadian plants and contractors, order custom yellow/black CAUTION signs as laser-engraved acrylic lamacoid plates on cautionsignss.com/labels/. Open the Sign Maker or Customize a stock legend, approve a to-scale proof, then same-day cut from Burlington with Canada Post shipping. No minimum order. These plates are not OSHA certified; provincial OH&S rules and your AHJ decide what must be posted. For a long list, email sales@llamacoids.ca or use the quote form.
What are custom caution signs made of?
Ours are laser-engraved acrylic lamacoid, a two-color engraving laminate. The laser cuts through the yellow surface so the black core forms the letters. The legend is part of the plate. Ink and vinyl sit on the surface and wear off sooner in the same spots.
When should I use CAUTION instead of WARNING or DANGER?
Use CAUTION for hazards that could cause minor or moderate injury. WARNING covers hazards that could kill or seriously injure. DANGER covers hazards that will. Your AHJ, provincial OH&S rules, and site program decide the final word for each location.
Are engraved caution labels better than caution stickers?
Engraved acrylic caution labels keep the legend readable where heat, wash-down, and handling peel vinyl stickers. Canadian shops use stickers for short-term barricades and engraved plates on finished equipment and permanent posts. Confirm your site program.
What sizes and mounting can I order?
Common wall sizes are 7 × 5 in and 10 × 7 in; strips such as 12 × 4 in fit door heads and beams; small tags start around 3 × 1 in. Choose adhesive, screw or rivet holes, or both, in 1/16 in or 1/8 in stock.
Can you make CSA-style caution signs from my list?
Yes. Paste the legends into the quote form or email sales@llamacoids.ca. We engrave a matched set and send a to-scale proof. Confirm your AHJ and site template before you lock the wording. We match the yellow/black CAUTION layout you send; we do not certify plates under OSHA or CSA.
Is there a minimum order?
No. Order one sign or a few hundred.
How fast can I get custom caution signs?
Most orders are cut the same day you approve the artwork proof. Free pickup in Burlington, or ship anywhere in Canada by Canada Post. Standard shipping is free on orders of $200 or more before tax.
What is the new Subrule 6 caution marking under Rule 2-100?
Under the 2024 Canadian Electrical Code / OESC Rule 2-100 Subrule 6, when the ampacity of service or feeder conductors based on loads calculated per Rules 8-200 or 8-202 is less than the fuse or circuit-breaker rating, a permanent, legible caution marking must be field-applied adjacent to the fused switch or breaker nameplate stating the maximum load permitted. Confirm your adopted edition and AHJ. This caution plate is separate from the panel directory required by Subrules 3–4. Order the yellow/black CAUTION plate in the Sign Maker with your ampere limit, or send the wording through the quote form.
Is CSA Z321 still the workplace sign standard in Canada?
CAN/CSA-Z321-96 (R2006) Signs and Symbols for the Workplace is withdrawn. Canadian workplaces often still use Z321-style shapes and colours alongside ANSI Z535-style signal-word headers, but provincial or territorial OH&S rules, your written safety program, and your AHJ have the final say. We engrave the yellow/black CAUTION layout you send; we do not certify plates under OSHA or CSA.