Fire sprinkler pipe marker
On sprinkler mains and cross mains, at valves, branches and wall penetrations.
Buildings & propertyASME A13.1CAN/CGSB-24.3
Pipe ID plates in the standard colour code: red for fire protection, green for water, blue for air and inert gas, yellow for steam, gas and fuel, orange for chemicals, brown for oils and purple for reclaimed water. Strap them to the pipe or stick them to the insulation jacket.
On sprinkler mains and cross mains, at valves, branches and wall penetrations.
On standpipe risers and the piping to hose valves in stairwells.
On the fire pump discharge and test header piping in the pump room.
On domestic cold water mains and risers, near valves, branches and wall penetrations.
On domestic hot water supply piping from the heater to the fixtures.
On the small return line that circulates domestic hot water back to the heater.
On chilled water supply mains; choose the left or right arrow to match the flow.
On chilled water return mains; choose the left or right arrow to match the flow.
On heating water supply mains from the boilers; choose the arrow that matches the flow.
On heating water return mains back to the boilers; choose the arrow that matches the flow.
On condenser water piping between the chillers and the cooling tower.
On feed water piping from the feed tank or deaerator to the boilers.
On glycol heating, cooling and snow-melt loops.
On compressed air mains and drops, showing the system pressure.
On nitrogen supply lines in plants, labs and refrigeration shops.
On the insulation jacket of steam mains and branches, showing the pressure class.
On condensate return lines from steam traps and receivers back to the boiler room.
On natural gas piping inside buildings, showing the operating pressure.
On propane piping from the tank or cylinder manifold to the appliances.
On fuel oil lines between the tank, the transfer pump and the burner or generator.
On chemical feed lines in pool, water treatment and cooling tower chemical rooms.
On lube oil lines on compressors, turbines and gearboxes.
On hydraulic lines on presses, lifts and hydraulic power units.
On reclaimed, rain and grey water piping, so no one ties a drinking water line into it.
On drinking water lines, to keep them clearly apart from process and non-potable water.
On process, raw and cooling water lines that are not safe to drink.
On fire service mains and fire protection water piping.
On sanitary drain and waste piping in ceilings and service rooms.
On roof drain and storm piping inside the building.
On plumbing vent stacks and vent headers.
On high pressure steam mains; add the operating pressure if you like.
On medium pressure steam mains between the boiler plant and the users.
On dry instrument air headers that feed controls and valve actuators.
On process and lab vacuum lines.
On industrial oxygen lines in welding shops and process plants.
On argon and shielding gas lines in welding and fabrication shops.
On glycol return piping, paired with the glycol supply marker.
On fuel oil return lines from the burner or generator back to the tank.
On air conditioning and furnace condensate drain lines.
On medical oxygen pipelines in hospitals, clinics and long-term care, in the green used for oxygen in Canada.
On medical air pipelines; black and white is the Canadian colour for medical air.
On medical vacuum (suction) pipelines in hospitals and clinics.
On nitrous oxide pipelines in hospitals and dental offices.
On softened water lines from the softener to boilers, kitchens and laundries.
On caustic feed lines in water treatment and process plants.
Build it from scratch in the sign maker, or send the wording through the quote form and we'll draw it for you.
References name the standard the wording usually comes from. Your inspector (the authority having jurisdiction) has the final say on wording, size and colour, so check the drawings or spec before you order.