ElectricalCECCSA Z462

Electrical code & equipment

Service, disconnect, transformer and capacitor warnings, plus the conductor and fuse tags an inspector looks for. Danger and warning plates for hazards, black and white for equipment ID.

  • 52 signs
  • From $2.25
  • Cut the same day
  • No minimum

52 signs and labels

Electrical code & equipment: all signs

Main service disconnect

On the service entrance switch or main breaker, with the system voltage and rating.

6 × 3″Red / White
$13.50 each

Service disconnect location

Where the main disconnect is out of sight, so firefighters and electricians can find it.

7 × 5″Blue / White
$26.25 each

Do not open under load

Isolating switches and bolted disconnects that are not rated to break load current.

7 × 5″Orange / Black
$26.25 each

Capacitor bank

Power factor correction and harmonic filter capacitor enclosures.

10 × 7″Red / White
$52.50 each
ISO 7010 W012

Transformer vault

Doors to transformer vaults and rooms with liquid-filled or dry-type units.

10 × 7″Red / White
$52.50 each

Keep 1 m clear, strip

A long, low strip above a row of panels or a switchboard line-up.

12 × 4″Blue / White
$36.00 each

Voltage present

Covers and doors over terminals that stay live, adhesive back.

5 × 3½″Red / White
$15.00 each
ISO 7010 M021

De-energize before servicing

Motor terminal boxes, control enclosures and luminaires that must be dead before work.

7 × 5″Orange / Black
$26.25 each
ISO 7010 W012

Exposed live parts

Inside dead-front doors and on barriers over bus that is live when the cover is off.

7 × 5″Red / White
$26.25 each

Utility CT cabinet

Current transformer and metering cabinets sealed by the utility.

6 × 3″Black / White
$13.50 each

Generator inlet

Beside a portable generator inlet with a breaker interlock.

10 × 7″Orange / Black
$52.50 each

Available fault current

Service equipment and switchboards, with the calculated value and the date it was worked out.

6 × 3″Black / White
$13.50 each

Replace fuses with

Inside fused switches, so the right class and rating goes back in.

4 × 2″Black / White
$6.00 each

Neutral

Neutral bars and neutral conductors in switchboards and splitters.

3 × 1″White / Black
$2.25 each

Grounding conductor

At the grounding electrode clamp and where the grounding conductor lands in the service.

6 × 2″Green / White
$9.00 each

Phase ID

Bus bars, feeders and terminations of phase A, in red to the CEC colour code (B black, C blue).

3 × 1″Red / White
$2.25 each

Series-rated combination

Panelboards and switchboards protected by a series-rated breaker combination, so only identical breakers go back in.

7 × 5″Yellow / Black
$26.25 each

Service disconnect 1 of 2

Buildings with two service disconnects; order a 2 OF 2 plate for the other one.

6 × 2″Red / White
$9.00 each

Not a service disconnect

Building mains and sub-mains that look like service equipment but are fed from another disconnect.

6 × 3″White / Red
$13.50 each
ISO 7010 W012

Supplied by two services

At each service and on equipment fed from more than one utility service.

10 × 7″Orange / Black
$52.50 each
ISO 7010 W012

Customer-owned high voltage

Substations, switchgear and transformers on the owner's side of the utility demarcation.

10 × 7″Red / White
$52.50 each
ISO 7010 W012

Load side may be energized

Disconnects and breakers whose load conductors can be backfed by a generator, UPS, PV system or another feeder.

7 × 5″Orange / Black
$26.25 each

Bonding jumper, do not remove

Water pipe, gas pipe and main bonding jumpers, so they stay on through plumbing and meter work.

4 × 2″Green / White
$6.00 each

Ground rod test well

Above or on ground rod test wells, numbered to match the grounding drawing.

4 × 2″Green / White
$6.00 each
ISO 7010 W017

Electric heater, hot surface

Beside baseboard, unit and duct heaters that run hot enough to burn and must not be covered.

7 × 5″Yellow / Black
$26.25 each

Shunt trip breaker

Breakers and switches with a shunt trip, so whoever finds one open checks the remote trip before resetting.

6 × 2″Black / White
$9.00 each

Maximum breaker or fuse size

Equipment and feeders, with the largest breaker or fuse the conductors and nameplate allow.

6 × 3″Black / White
$13.50 each

Utility meter location

At the service when the revenue meter is in another room, for meter readers and utility crews.

6 × 2″Black / White
$9.00 each
ISO 7010 P010

High voltage, do not touch

On enclosures, bus ducts and equipment that the public or other trades can reach.

10 × 7″Red / White
$52.50 each
ISO 7010 W012

Live wires, keep away

Construction and renovation sites with energized temporary wiring or open boxes.

10 × 7″Red / White
$52.50 each
ISO 7010 W012

Buried high voltage cable

Marker posts and fences along underground primary feeders and duct banks on private property.

10 × 7″Orange / Black
$52.50 each
ISO 7010 W012

Low overhead wires

Yards, lanes and loading areas where trucks, booms and dump boxes pass under service drops or lines.

10 × 7″Yellow / Black
$52.50 each
ISO 7010 W017

Transformer, keep clear

Dry-type transformers in electrical rooms and on mezzanines, where storage blocks the vents.

10 × 7″Yellow / Black
$52.50 each
ISO 7010 P009

High voltage, do not climb

Substation fences, poles, towers and structures carrying overhead conductors.

10 × 7″Red / White
$52.50 each
ISO 7010 P023

Electrical panel, do not block

Above panels in storage rooms, garages and warehouses where stock and carts creep in front.

7 × 5″White / Red
$26.25 each

Electric heat tracing

On the insulation jacket of heat-traced pipes and vessels, so nobody cuts into a live cable.

6 × 3″Yellow / Black
$13.50 each

Line terminals stay energized

Inside main breakers and service disconnects, where the line terminals stay live with the handle off.

7 × 5″Orange / Black
$26.25 each

No metal ladders

Electrical rooms, substations and work near overhead lines, so only non-conductive ladders are used.

7 × 5″Yellow / Black
$26.25 each

Voltage plate, 120/208 V

Panels, enclosures and equipment covers on 120/208 V three-phase systems.

4 × 2″Red / White
$6.00 each

Voltage plate, 120/240 V

Residential and small commercial panels and equipment on single-phase 120/240 V service.

4 × 2″Red / White
$6.00 each

Voltage plate, 347/600 V

Switchboards, panels and enclosures on 347/600 V four-wire systems, the common Canadian commercial voltage.

4 × 2″Red / White
$6.00 each
ISO 7010 W012

Voltage sign, 13,800 V

Doors and fences of 13.8 kV switchgear rooms, substations and customer-owned primary equipment.

10 × 7″Red / White
$52.50 each
ISO 7010 W012

Voltage sign, 27,600 V

Doors and fences of 27.6 kV switchgear, transformer rooms and substations, common on Ontario distribution.

10 × 7″Red / White
$52.50 each
ISO 7010 W012

Voltage sign, 44,000 V

Fences and gates of 44 kV substations and customer-owned supply stations.

10 × 7″Red / White
$52.50 each

High-resistance grounded system

Service switchboards and MCCs on high-resistance grounded systems, where a first ground fault does not trip.

7 × 5″Orange / Black
$26.25 each

Ungrounded system

Switchboards on ungrounded delta systems, so workers check the ground detector before starting.

7 × 5″Orange / Black
$26.25 each

References name the standard the wording usually comes from. Your inspector (the authority having jurisdiction) has the final say on wording, size and colour, so check the drawings or spec before you order.