Fire extinguisher, wall strip
Above wall-mounted extinguishers, so they can be seen down a corridor.
Fire, exit & emergencyOntario Fire CodeNFPA 10
Extinguisher, hose cabinet, sprinkler, standpipe and fire department connection signs, plus the riser, valve, drain and hydrant tags inspectors check. Red plate, white letters, so responders find them fast.
Above wall-mounted extinguishers, so they can be seen down a corridor.
Above the Class K extinguisher in commercial kitchens with a hood suppression system.
On or above hose cabinets and hose stations.
Each sprinkler control valve, with the zone or area it serves.
Sprinkler and standpipe valves that must stay open.
The inspector's test connection on each sprinkler system or zone.
Under the exterior water-flow alarm bell, so passers-by know to call.
Standpipe hose valves in stairwells, with the stair and floor.
The main drain on each sprinkler riser.
Remote annunciator panels at the main entrance or fire department response point.
Beside the exterior key box that holds building keys for responders.
Above extinguishers, hose cabinets and valves in storage areas and warehouses.
On the spare sprinkler cabinet next to the riser.
Above manual pull stations that are hard to spot from down a corridor or across a plant floor.
Above the fire blanket in kitchens, labs and welding bays.
On closed extinguisher cabinets and cupboards, so the extinguisher is found without opening every door.
Above CO2 extinguishers in electrical rooms, server rooms and switchgear areas.
On each sprinkler riser, with the system type and the floors it serves.
The alarm check valve on a wet sprinkler riser.
The dry pipe valve serving loading docks, parking garages and other unheated areas.
Each low point (auxiliary) drain on a dry sprinkler system, so they are all found and drained before a freeze.
On or beside the post indicator valve that controls the underground supply to the sprinklers.
Sprinkler and standpipe control valves that must not be shut without telling the fire department.
Above the fire pump test header on the outside wall, so responders do not mistake it for the fire department connection.
Above the firefighters' smoke control panel at the central alarm and control facility.
At the ground-floor lobby of the elevator designated for firefighters' use.
Bolted to each private fire hydrant on a plant, campus or industrial park, numbered to match the site plan.
Above extinguishers on walls and columns, with the ISO extinguisher symbol so it reads at a glance.
Above hose cabinets and hose reels, with the ISO fire hose symbol.
Above manual pull stations so they can be found down a corridor or across a plant.
Location sign above a wall-mounted fire blanket in kitchens, labs and shops.
Fire points and cabinets that hold extinguishers, hose and other firefighting gear.
Door strip for rated doors that keep getting wedged or hooked open.
Doors held open on magnetic hold-opens that release and close when the alarm sounds.
Warehouse and storage room walls, where stock gets stacked up into the sprinkler heads.
Near exposed sprinkler piping in shops, warehouses and parkades where people hang cords and signs.
On dry standpipe hose outlets in parking garages and unheated stairs.
Posted at entrances while the alarm or sprinkler system is shut down and a fire watch is patrolling.
Hung on the riser or control valve while the sprinkler system is impaired.
Above or on the bracket of multipurpose dry chemical extinguishers.
Above pressurized water extinguishers, so nobody grabs one for an electrical or grease fire.
Above dry powder extinguishers in machine shops that cut magnesium, titanium or other metals.
At every entrance to rooms protected by a total-flooding carbon dioxide system.
At the main entrance and fire department access point of a fully sprinklered building.
On glass-front cabinets for hose, extinguishers, keys or axes.
On rated walls above the ceiling, so every trade firestops the holes they make.
On ceiling and duct access doors in front of fire dampers that need regular inspection.
On ceiling and duct access doors in front of smoke dampers.
Above the manual pull station for the hood fire suppression system, on the way out of the kitchen.
Above wall-mounted extinguishers, so they can be found from down the corridor.
Build it from scratch in the sign maker, or send the wording through the quote form and we'll draw it for you.
References name the standard the wording usually comes from. Your inspector (the authority having jurisdiction) has the final say on wording, size and colour, so check the drawings or spec before you order.